Authors: Daxini, Sachin C.; | Nichol, Jason W.; | Sieminski, Alisha L.; | Smith, Geoffrey | Gooch, Keith J.; | Shastri, V. Prasad; ; ; ;
Affiliations: Masters in Biotechnology Program, School of Engineering and Applied Science, University of Pennsylvania, Philadelphia, PA, USA | Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA | Institute for Medicine and Engineering, University of Pennsylvania, Philadelphia, PA, USA | Department of Materials Science and Engineering, University of Pennsylvania, Philadelphia, PA, USA | Department of Biomedical Engineering, Ohio State University, Columbus, OH, USA | Joseph Stokes Jr. Research Center, Children's Hospital of Philadelphia, USA | Department of Biomedical Engineering, Vanderbild University, Nashville, TN, USA
Note: [] Equally contributing authors.
Note: [] Address for correspondence: Dr. V. Prasad Shastri, 5824 Stevenson Center, Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37232, USA. Tel.: + 615 322 8005; Fax: +1 615 343 7919; E-mail: [email protected].
Abstract: The use of synthetic polymeric vascular grafts is limited by the thrombogenecity of most biomaterials. Efforts to reduce thrombogenicity by seeding grafts with endothelial cells, the natural non-thrombogenic lining of blood vessels, have been thwarted by flow-induced cell detachment. We hypothesized that by creating well-defined micro-textured patterns on a surface, fluid flow at the surface can be altered to create discrete regions of low shear stress. We further hypothesized that, due to reduced shear stress, these regions will serve as sanctuaries for endothelial cells and promote their retention. To test these hypotheses, well-defined micro-textured polyurethane (PU) surfaces consisting of arrays of parallel 95-micron wide and 32-micron deep channels were created using an etched silicon template and solvent casting techniques. Based on computational fluid dynamics, under identical bulk flow conditions, the average local shear stress in the channels (46 dyn/cm2) was 28% lower than unpatterned surfaces (60 dyn/cm2). When PU surfaces pre-seeded with endothelial cells (EC) were exposed to the same bulk flow rate, EC retention was significantly improved on the micropatterned surfaces relative to un-patterned surfaces (92% vs. 58% retention).
Keywords: Endothelial cells, microfabrication, retention, computational fluid dynamics, vascular grafts, tissue engineering
Journal: Biorheology, vol. 43, no. 1, pp. 45-55, 2006
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]