Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Purvis Jr., N.B. | Giorgio, T.D.
Affiliations: Department of Chemical Engineering, Vanderbilt University, Nashville, TN 37027, USA (Whitaker Foundation support)
Note: [] Accepted by: Editor V.A. Parsegian
Abstract: Hemodynamic shear is known to stimulate blood and endothelial cells and induce platelet activation. Many studies of shear-induced platelet stimulation have employed rotational visco meters in which secondary flow effects are assumed to be negligible. Shear induced platelet activation occurs at elevated shear rates where secondary flows may contribute a significant percentage of the total hydrodynamic force experienced by the sample. Elongational stress, one component of this secondary flow, has been shown to alter transmembrane ion flux in intact cell and the permeability of synthetic membrane preparations. Elongational flow also occurs in the vasculature at sites of elevated shear stress. Secondary flow components may contribute to platelet activation induced during shear stress application in rotational viscometry. A unique ‘constrained convergence’ elongational flow chamber was designed and fabricated to study platelet response to elongational stress exposure. The elongational flow chamber was capable of producing an elongation rate of 2.1 s−1 with a corresponding volume averaged shear rate of 58.33 s−1. Significant changes were observed in the total platelet volume distribution and measured response to added chemical antagonist after elongational stress exposure. The total platelet volume histogram shifted toward larger particle sizes, suggesting the formation of large aggregates as a result of elongational stress exposure. Platelets exposed to elongational stress demonstrated a dose dependent decrease in added ADP-induced aggregation rate and extent of aggregation.
Keywords: Platelets, extensional, shear stress, aggregation, activation, elongational
DOI: 10.3233/BIR-1991-28501
Journal: Biorheology, vol. 28, no. 5, pp. 355-367, 1991
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]