Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Huang, C.R.a | Pan, W.D.a | Chen, H.Q.b | Copley, A.L.c
Affiliations: [a] Department of Chemical Engineering & Chemistry, New Jersey Institute of Technology, Newark, New Jersey 07102, USA | [b] Institute of Biomedical Engineering, West China University of Medical Sciences, Chengdu, Sichuan, People’s Republic of China | [c] Laboratory of Biorheology, Polytechnic University, Brooklyn, New York 11201, USA
Note: [] Accepted by: Editor Y.C. Fung
Abstract: The steady state non-Newtonian viscosity of whole human blood has been widely studied as a function of the shear rate; and used to characterize the blood in various pathological disorders. In our previous studies, we demonstrated that blood is a thixotropic fluid. Its time-dependency and shear rate dependency of rheological behavior can be represented by an equation developed by Huang. Parameters of the equation can be used for the characterization of an individual’s blood. They provide information, such as the kinetic rate constant of breakdown of RBC rouleaux to individual erythrocytes and the relative amount of rouleau formation in the dynamic equilibrium between rouleaux and individual erythrocytes. In this communication, the thixotropic parameters from blood samples of fifteen apparently healthy human subjects were investigated. When compared to the use of apparent viscosity values for the correlation with a pathological disorder, thixotropic parameters are preferable. The mean values of thixotropic parameters obtained from apparently healthy human subjects provide a base for comparison with the same parameters as obtained from blood samples of patients with certain pathological disorders involving the circulation.
Keywords: Blood thixotropy, erythrocyte rouleaux, hemorheology, Huang thixotropy equation, pathological conditions
DOI: 10.3233/BIR-1987-24630
Journal: Biorheology, vol. 24, no. 6, pp. 795-801, 1987
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]