Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Workshop: Breaking Symmetry in Haemodynamics, London, UK, 23–24 April 2001
Article type: Research Article
Authors: Sherwin, S.J. | Doorly, D.J. | Franke, P. | Peiró, J.
Affiliations: Biomedical Flow Group, Department of Aeronautics, Imperial College of Science, Technology and Medicine, Prince Consort Road, London, UK
Note: [] Address for correspondence: Dr. S.J. Sherwin, Department of Aeronautics, Imperial College of Science, Technology and Medicine, Prince Consort Road, London, SW7 2BY, UK. Tel.: +44 207 594 5053; Fax: +44 207 584 8120; E‐mail: [email protected].
Abstract: Building on previous studies of unsteady flow within model distal bypass grafts we analyse the near wall residence times and shear exposure in a 45 degrees anastomosis under symmetrical and symmetry breaking geometric configurations. We define residence time as the minimum time for a particle to exit a spherical region and shear exposure as a temporal integral of the Huber‐Henky‐von‐Mises criterion along a particle path over a fixed time interval. Decomposing the pulsatile cycle into four equal intervals we find that the interval of peak residence time in the host vessel is from mid‐deceleration to peak diastole and peak diastole to mid‐acceleration. The asymmetric model is shown to have a significantly lower residence time during these intervals. Considering the shear exposure prior to the residence time evaluation we determine that a higher average shear exposure exists in the asymmetric model associated with the upstream geometry modification. Analysis of the regions of high residence time and shear exposure suggests that the “toe” region and the interface between the “heel” and bulk flow are more significant than the bed and heel region. Although the asymmetric model considered in this study reduces residence times in the host artery, the product of the measure of shear exposure and residence time is not found to be preferable. If shear exposure were to be considered as an important factor in particle activation, the findings imply that for junction optimisation, greater consideration needs to be given both to the local junction asymmetry and upstream influence on the shear history.
Journal: Biorheology, vol. 39, no. 3-4, pp. 365-371, 2002
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]