Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Proceedings of the Fourth International Congress of Biorheology. Jikei University School of Medicine, Tokyo, Japan, 27 July – 1 August 1981. Dedicated to Alex Silberberg
Guest editors: Alfred L. Copley
Article type: Research Article
Authors: Fung, Yuan-Cheng
Affiliations: Department of AMES-Bioengineering, M-005, University of California, San Diego, La Jolla, California 92093
Abstract: The pulmonary capillary blood vessels have a unique planar sheet-like geometry with thickness about the same as the diameter of the red cells. The hemorheological properties of the blood in such a network is dominated by the interaction between the red cells and the capillary vessel wall. A distinctive feature of the blood flow in pulmonary capillaries is the non-uniformity in the distribution of red blood cells in the alveolar walls. To explain this nonuniformity, we showed that in branching capillaries the hematocrit distribution depends on the velocity distribution. If a vessel bifurcates and if the velocities in the daughter branches are unequal, then the faster side gets more red cells. If the velocity ratio exceeds certain critical value about 2.5 (with exact value depending on cell rigidity, tube diameter and hematocrit), then the slower branch gets no red cell at all, (i.e. hematocrit → 0). Another reason for the nonuniform hematocrit distribution is due to occasional plugging of small blood vessels by leukocytes. The force of interaction between leukocytes and the vascular enothelium is determined. Turning to the blood flow, we show that it is affected critically by the elasticity of the blood vessels. In recent years we measured the distensibility of pulmonary capillaries and arterioles or venules of the cat by the polymer casts method, and arteries and veins of diameter 100 μm and up by the x-ray method. Thus the elasticity of all blood vessels of the cat’s lung is now determined. With this information the nonlinear pressure and flow relationship is determined. Furthermore, we have shown that all pulmonary veins, including the venules, remain patent (not collapsed) under negative transmural pressure as large as −17 cm H2O. This important fact tells us that in the sluicing condition of zone 2 (where the pulmonary venous pressure is lower than the alveolar gas pressure), the sluicing gate must be located at the exit ends of the alveolar capillary sheets. With this information the flow limitation problem is solved.
Keywords: Pulmonary blood flow, Hematocrit distribution
DOI: 10.3233/BIR-1982-191-209
Journal: Biorheology, vol. 19, no. 1-2, pp. 79-94, 1982
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]