Abstract: BACKGROUND: Deep vein thrombosis and the risk of pulmonary embolism are significant causes of morbidity and mortality. Much remains unclear, however, about the mechanisms by which a venous thrombus initiates, progresses, or resolves. In particular, there is a pressing need to characterize the evolving mechanical properties of a venous thrombus for its mechanical integrity is fundamental to many disease sequelae. OBJECTIVE: The primary goal of the present study was to initiate a correlation between evolving histological changes and biomechanical properties of venous thrombus. METHODS: We employed an inferior vena cava ligation model in mice to obtain cylindrical samples of thrombus that were well suited for mechanical testing and that could be explanted at multiple times following surgery. Using uniaxial micro-mechanical testing, we collected stress–stretch data that were then fit with a microstructurally-inspired material model before submitting the samples to immunohistological examination. RESULTS: We found that venous thrombus underwent a radially inward directed replacement of fibrin with collagen between 2 weeks and 4 weeks of development, which was accompanied by the infiltration of inflammatory and mesenchymal cells. These histological changes correlated with a marked increase in material stiffness. CONCLUSIONS: We demonstrated that 2 to 4 week old venous thrombus undergoes drastic remodeling from a fibrin-dominated mesh to a collagen-dominated microstructure and that these changes are accompanied by dramatic changes in biomechanical behavior.
Keywords: Venous ligation, intraluminal thrombosis, stiffness, stress, clot
DOI: 10.3233/BIR-15058
Journal: Biorheology, vol. 52, no. 3, pp. 235-245, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]