Article type: Research Article
Authors: Hartert, H. | Schaeder, J.A.
Affiliations: Medizinische Universitätsklinik, Heidelberg, Bergheimer Str. 58, Germany
Abstract: The thrombelastograph records continuously the shear modulus of the clot from the very beginning of the clotting reaction. The shear modulus of a normal plasma clot at the end of the clotting process is about 5000 dyn/cm2, i.e. about 600–2400 times less than that of rubber. A clot of normal native blood has approximately the same shear modulus as that of recalcified plasma with a normal platelet count. The adherence of the clot in the measuring device of the apparatus ensures that retraction is negligible. The measured shear modulus includes the retractive force and the shear modulus of the fibrin in varying proportions. In the glass tube, on the other hand, the retraction process and the fibrin shear modulus operate in opposite directions. The physical property of a blood or plasma clot here discussed is a combination of several effects, such as platelet number and viability, fibrinogen concentration, ionic milieu and the retraction cofactor, which seem to influence the mechanical strength and the elastic tension of the clot. Compared with it, a clot from purified fibrinogen and thrombin is a very weak material. Recently reestablished “normal values” of the constants from the thrombelastograph for normal native blood were: r=12 min 26 sec (s=±1 min 34 sec), k=5 min 35 sec (s=±1 min 1 sec), me=108 (s=±17.7). The male group had the same values as the female one. According to several authors, citrated or oxalated blood or plasma have widely different values depending on the varying methods of decalcification and recalcification.
DOI: 10.3233/BIR-1962-1105
Journal: Biorheology, vol. 1, no. 1, pp. 31-39, 1962
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]