Article type: Research Article
Authors: Wang, Shuang; ; | Zhao, Jianhua; | Lui, Harvey; | He, Qingli | Zeng, Haishan; ;
Affiliations: Cancer Imaging Department, British Columbia Cancer Agency Research Centre, Vancouver, BC, Canada | Laboratory for Advanced Medical Photonics, Photomedicine Institute, Department of Dermatology and Skin Science, University of British Columbia and Vancouver Coastal Health Research Institute, Vancouver, BC, Canada | Department of Physics, Northwest University, Xi'an, Shaanxi, China
Note: [] Corresponding author: Dr. Haishan Zeng, Cancer Imaging Department, British Columbia Cancer Agency Research Centre, 675 West 10th Avenue, Vancouver, BC, V5Z 1L3, Canada. Tel.: +1 604 675 8083; Fax: +1 604 675 8099; E-mail: hzeng@ bccrc.ca.
Abstract: Raman spectroscopy has been used as a sensitive tool for studying biological tissue and evaluating disease. In many applications, microscopic level resolution spectral analysis is desirable. And this has been performed mostly by expensive commercial confocal micro-Raman systems. In this research, we present a simple method for building an economical and modular Raman microspectroscopy system that combines a microscope with a Raman spectrometer using an optical fiber bundle. The bundle with a circular collection end is positioned at an image plane of the microscope to collect Raman signals from the interested micro-location on the sample. The light delivery end is specially configured so that its 37 fibers are arranged along a straight line to fit into the spectrometer entrance slit. This configuration improves light collection efficiency and maintains high spectral resolution. To battle the great background autofluorescence and Raman signals that could originate from the microscope slides and optics due to the non-confocal set-up of our simplified system, conventional normal-incident illumination is replaced by oblique illumination at 45° degrees and the microscope slides are coated with gold. We demonstrated the usefulness of the system by measuring micro-Raman spectra from different skin layers on vertical sections of normal skin tissue samples.
Keywords: Microscopy Raman, near infrared fluorescence imaging, gold-coated slide, oblique illumination, tissue Raman spectroscopy, skin
DOI: 10.3233/SPE-2010-0487
Journal: Spectroscopy, vol. 24, no. 6, pp. 577-583, 2010
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]