Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Lázaro, João Carlos | Pacheco, Marcos Tadeu T. | Rodrigues, Kátia Calligaris | de Lima, Carlos José | Moreira, Leonardo Marmo; | Villaverde, Antonio Balbin | Silveira Jr., Landulfo
Affiliations: Instituto de Pesquisa e Desenvolvimento, Universidade do Vale do Paraíba, São José dos Campos, SP, Brazil | Núcleo de Engenharia Biomédica, Universidade Camilo Castelo Branco, São José dos Campos, SP, Brazil
Note: [] Corresponding author: Leonardo Marmo Moreira, Instituto de Pesquisa e Desenvolvimento, Universidade do Vale do Paraíba, Av. Shishima Hifumi, 2911, 12244-000, São José dos Campos, SP, Brazil. E-mail: [email protected].
Abstract: The present work is focused on the influence of the slit aperture and time exposure of the infrared light on the Charge Coupled Device (CCD) in relation to their physical effects, in order to improve the Raman spectrum characteristics. Indeed, the alterations in slit aperture and CCD time exposure affect significantly important spectral properties, such as the spectral intensity, Signal to Noise Ratio (SNR) and band width resolution of the Raman spectra. Therefore, the present proposal has the aim of to found the optimum conditions of instrumental arrangement, involving the minimum collection time and maximum signal quality in dispersive Raman spectrometers. Samples of dehydrated human teeth and naphthalene were evaluated with a Raman dispersive spectrometer employing excitation wavelength of 830 nm in several integration times and spectrometer slit apertures. The analysis of the spectral intensity, SNR and band width of selected Raman peaks allowed to infer that these properties of a dispersive Raman spectrum depend directly of the exposure time on the detector as well as spectrograph slit aperture. It is important to register that the higher SNR was obtained with higher exposure time intervals. To the samples evaluated in the present article, the band width has lower values for slit apertures of 100–150 μm, i.e., in this aperture range the spectral resolution is maximum. On the other hand, the intensity and SNR of the Raman spectra becomes optimal for slit apertures of 150–200 μm, since this aperture does not affect significantly the integrity of the Raman signal. In this way, we can to propose that in approximately 150 μm, it is possible to obtain an optimum condition, involving spectral resolution as well as SNR and spectral intensity. In any case, depending of the priorities of each spectral measurement, the instrumental conditions can be altered according with the necessities of each specific chemical analysis involving a determined sample. The present data are discussed in details in agreement with recent data from literature.
Keywords: Raman spectroscopy, spectral resolution, band width resolution, signal to noise ratio (SNR)
DOI: 10.3233/SPE-2009-0377
Journal: Spectroscopy, vol. 23, no. 2, pp. 71-80, 2009
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]