Note: [] Corresponding author: Prof. Andrew Macnab, Distinguished Scholar in Residence, Peter Wall Institute for Advanced Studies, University of British Columbia, Room L317, Mail Box 80, Children's & Women's Health Centre, 4480 Oak St, Vancouver, BC, V6H 3V4, Canada. Tel.: +1 604 875 3524; Fax: +1 604 875 2890; E-mail: [email protected].
Abstract: We wished to use near infrared spectroscopy (NIRS) to evaluate changes in blood perfusion in the liver and small bowel. However, conventional clinical NIRS probes use adhesive light shielding appliqués that fail in direct contact with the wetness and softness of the liver and small bowel surfaces. We describe our development and testing of customized NIRS probe holders. Methods: Studies were conducted in 11 juvenile (9–17 kg) anesthetized Yorkshire piglets, with intact liver and bowel exposed during experimental septic shock induced by infusion of Escherichia coli. Internally, the emitter and detector of one NIRO-300 channel were sheathed, directed towards each other, and affixed to the opposite arms of a long-jawed ratchet clamp applied directly to the liver. The emitter and detector of the NIRO-300's second channel were applied, facing each other, on opposite inner surfaces of a semicircular, semi-rigid, reinforced rubber tube through which a loop of the small bowel was drawn. Externally, optodes from a NIRO-500 were applied to the skin over the liver. NIRS data were collected at 1second intervals for 180 minutes. Results: A wide range of optical neutral density filters was required to attenuate the emissions because of the diversity of tissue density between subjects. There were no complications with the liver clamp, and the initial tendency for the bowel to slip from the NIRS holder was solved by securing it with surgical ribbon. Conclusion: Since the NIRO-300 control algorithm did not halt monitoring; the NIRO-300 data correlated with the NIRO-500 data (r2=0.292 to 0.659) and both were correlated with the mean arterial blood pressure (range: r2=0.309 to 0.918, p<0.05 for r2>0.105), our modifications were deemed successful.
Journal: Spectroscopy, vol. 20, no. 5-6, pp. 253-259, 2006
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]