Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Guimarães, A.E. | Pacheco, M.T.T. | Silveira Jr., L. | Barsottini, D. | Duarte, J. | Villaverde, A.B. | Zângaro, R.A.
Affiliations: Institute of Research and Development (IP&D), Universidade do Vale do Paraíba (UNIVAP), Av. Shishima Hifumi, 2911, Urbanova, São José dos Campos, ZIP 12244-000, SP, Brazil
Note: [] Corresponding author: Prof. Landulfo Silveira Junior, Institute of Research and Development (IP&D), Universidade do Vale do Paraíba (UNIVAP) Av. Shishima Hifumi, 2911 – Urbanova – São José dos Campos 12244-000, SP, Brazil. Tel.: +155 12 3947 1124; Fax: +155 12 3947 1149; E-mail: [email protected].
Abstract: This paper reports the application of near-infrared Raman spectroscopy to detect ephedrine in biological medium. At present time, the doping control for ephedrine in athletes uses the urinalysis by the gas chromatography/mass spectrometry, with main disadvantage the need of collecting urine and the time delay to obtain results. This work aims to develop a noninvasive technique that will allow to evaluate the concentration of the ephedrine in a real time diagnosis. A Raman system composed by a Ti:Saphire laser pumped by an Argon laser was used, operating at the wavelength of 785 nm, with a laser power of 70 mW at sample position. Raman scattered photons were collected by a f/l.8 spectrometer and a N2-cooled CCD detector. Ephedrine Raman peaks at 1002 and 1603 cm−1 were studied, opening possibility for the identification and quantification of ephedrine. Raman spectra of ephedrine with different concentrations in human urine were taken, and the intensity of the ephedrine peak at 1002 cm−1 was measured as a function of its concentration. It was also studied the Raman spectrum of an urine sample from a Wistar rat, after a subcutaneous inoculation of an ephedrine solution in physiologic serum, at the concentration of 5 mg/ml. It was found that Raman spectroscopy could detect ephedrine in urine at concentrations lower than the doping limit legally permitted by the International Olympic Committee.
Keywords: Near-infrared Raman spectroscopy, doping control, ephedrine, noninvasive diagnosis
Journal: Spectroscopy, vol. 20, no. 4, pp. 185-194, 2006
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]