Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Second International Conference on Biomedical Spectroscopy: From the Bench to the Clinic, London, UK, 5–8 July, 2003
Article type: Research Article
Authors: Schilling, Stephan | Demuth, Hans‐Ulrich
Affiliations: Probiodrug AG, Weinbergweg 22, 06120 Halle/Saale, Germany
Note: [] Corresponding author: H.‐U. Demuth, Probiodrug AG, Weinbergweg 22, 06120 Halle, Germany. Tel.: +49 345 5559900; Fax: +49 345 5559901; E‐mail: Hans‐[email protected].
Abstract: Glutaminyl cyclase (QC, EC 2.3.2.5) catalyses the formation of pyroglutamyl residues from glutamine at the N‐terminus of peptides and proteins. In previously applied assays, QC activity was determined by either analysing the products formed using HPLC coupled with photometric or fluorometric detection, radioimmunoassay, or by detecting the release of ammonia spectrophotometrically. Although these methods are sensitive, they are all discontinuous and therefore time‐consuming and laborious. To conduct a detailed kinetic investigation of QC catalysis, we developed coupled continuous assays suitable for microplates which allow now convenient determination of QC activity. The methods either use pyroglutamyl aminopeptidase or glutamate dehydrogenase as auxiliary enzymes, which results in the liberation of chromophores or fluorophores such as pNA, AMC, βNA or in the conversion of the chromophore NADH/H+ into NAD+, respectively. The assays were applied in various enzyme isolation and characterisation studies, using crude protein solutions as well as purified enzyme in pH‐dependence, substrate and inhibitor specificity investigations. Depending on the respective analytical task, both assays complement each other. Therefore, different enzymatic properties could be explored in more detail. Since the employed strategy of assay development could be of interest also for the analysis of other enzymes, the methods are described here in a comprehensive manner.
Journal: Spectroscopy, vol. 18, no. 2, pp. 363-373, 2004
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]