Authors: Washabaugh, Edward P.a; c | Krishnan, Chandramoulia; b; c; *
Affiliations: [a] Department of Physical Medicine and Rehabilitation, University of Michigan Medical School, Ann Arbor, MI, USA | [b] School of Kinesiology, University of Michigan, Ann Arbor, MI, USA | [c] Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
Correspondence: [*] Corresponding author: Chandramouli Krishnan, Director, Neuromuscular & Rehabilitation Robotics Laboratory (NeuRRo Lab), Department of Physical Medicine and Rehabilitation, University of Michigan, 325 E Eisenhower Parkway (Suite 3013), Ann Arbor, MI - 48108, USA. Tel.: +1 319 321 0117; Fax: +1 734 615 1770; E-mail: [email protected].
Abstract: Purpose: Accurate coil placement over a target area is critical during transcranial magnetic stimulation (TMS), as small deviations can alter testing outcomes. Accordingly, frameless stereotaxic systems (FSS) are recommended for reliable coil placement during TMS applications. However, FSS is not practical due to the cost associated with procuring such systems. Therefore, the purpose of this study was to develop a low-cost TMS coil tracking approach using simple webcams and an image processing algorithm in LabVIEW Vision Assistant. Methods: A system was created using two webcams, retroreflective markers, and computer stereovision, for tracking the TMS coil over a target area. Accuracy of the system was validated in both the global and local reference frames, while repeatability was measured within- and between-days for placement of the TMS coil over the target area relative to the head. The feasibility of our system was also verified by collecting motor evoked potentials (MEPs) of first dorsal interosseous muscle from human subjects. Results: The results of this study indicated that the system was highly accurate and repeatable, and could track the coil position with <5 mm error and orientation <1.1° error from the target. We also observed larger and more consistent MEPs when stimulating the brain using feedback from the coil tracking system than when the examiner attempted to stimulate without any feedback. Conclusion: The findings suggest that webcam-based coil tracking is a feasible low-cost solution to track coil positions during TMS procedures.
Keywords: Neuronavigation, motion tracking, motor mapping, real time, stereotaxy
DOI: 10.3233/RNN-150609
Journal: Restorative Neurology and Neuroscience, vol. 34, no. 2, pp. 337-346, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]