Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Scherman, Peter | Kanje, Martin | Dahlin, Lars B.
Affiliations: Department of Hand Surgery, Malmö University Hospital, Malmö, Sweden | Department of Animal Physiology, Lund University, Lund, Sweden
Note: [] Corresponding author: Peter Scherman, Department of Hand Surgery, Malmö University Hospital, S-205 02 Malmö, Sweden. Tel.: +46 40 33 17 25; Fax: +46 40 92 88 55; E-mail: Peter. [email protected]
Abstract: Purpose: We investigated whether sutures could guide regeneration across bifurcated nerve defects and how the number of sutures influenced regeneration. Methods: Bilateral ten mm defects in the rat sciatic nerve were bridged by either two or six laps of longitudinal (8/0 polyglactin) sutures. Bilateral ten mm defects including the bifurcation of tibial and peroneal nerves were bridged by two laps to the tibial and four laps to the peroneal nerve on one side and vice versa on the other. Evaluation of tetanic force, weights of the gastrocnemius and caudal tibial muscles and morphometry of the nerves were performed at twelve weeks. Results: Simple defects bridged by six laps yielded a significantly greater number of myelinated axons compared to two laps. In the bifurcated defects a well defined two branched nerve structure was formed in all cases between the sciatic nerve and its peroneal and tibial branches. However, in the bifurcated model the tibial nerve attracted more axons than the peroneal irrespective of the number of suture laps. Conclusions: There is no simple correlation between the number of sutures and the number of regenerating axons but two suture laps may be insufficient for the repair of a rat sciatic nerve. Sutures supported reconstruction of new fascicles across bifurcated nerve defects.
Keywords: suture, nerve regeneration, bifurcation, tetanic force, muscle weight
Journal: Restorative Neurology and Neuroscience, vol. 23, no. 2, pp. 79-85, 2005
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]