Abstract: BACKGROUND: Fascial dehiscence after spinal instrumentation is usually located at the mechanically stressed interscapular thoracic spine and often causes cosmetic impairment and pain. However, therapy options remain barely discussed. Synthetic meshes have been successfully used in the treatment of abdominal hernias. OBJECTIVE: It was hypothesized that synthetic meshes are a successful treatment option for spinal fascial dehiscence. METHODS: This retrospective study of a prospective database investigated all consecutive patients who received a synthetic mesh for a fascial dehiscence of the spine between 2010 and 2014 after prior spinal instrumentation. Primary outcomes were healing of the fascial dehiscence, recurrence, infection, revision, subjective satisfaction on a visual analog scale (VAS), and the Oswestry Disability Index (ODI). Among others, secondary outcomes consisted of seroma formation and return to work. The evaluated risk factors consisted of the body mass index (BMI), outer abdominal fat (OAF), back tissue, smoking, immunomodulatory therapy, preoperative radiation dose, and instrumented levels. RESULTS: Sixteen patients with a mean follow up of 24 (SD 15) months were included. Every fascial dehiscence successfully healed with the synthetic mesh and there were no recurrences, infections or revisions. The mean subjective satisfaction level was VAS 7.3 and the mean ODI was 26%. Five (31%) patients had a seroma postoperatively, but did not show any differences in the outcome (e.g. ODI of 28%). In the patient group < 65 years (n = 12), all but two patients, who had work restrictions due to other diseases, regained at least some capacity to work. Worse ODI scores were found for patients with increased BMI, OAF, back tissue, cortisone therapy, instrumented levels, preoperative radiation dose, and smokers. CONCLUSION: Synthetic meshes are a successful treatment option for spinal fascial dehiscence, even seemingly in patients with a higher risk profile such as obese and immunocompromised patients as well as in revision procedures. They are associated with respectable cosmetic results, pain relief and clinical outcome. Postoperatively, it is recommended to leave drains for more than five to seven days in order to avoid seroma formation and to avoid weight training for six weeks. Further prospective, comparative studies are recommended.
Keywords: Synthetic mesh, spinal fascial dehiscence, instrumentation of the spine, Oswestry Disability Index (ODI), patient satisfaction
DOI: 10.3233/BMR-160728
Journal: Journal of Back and Musculoskeletal Rehabilitation, vol. 30, no. 1, pp. 153-162, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]