Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Marcolino, Alexandre Márcioa; b; * | Fonseca, Marisa de Cássia Registrob | Leonardi, Naiara Taisc | Barbosa, Rafael Inácioa; b | Neves, Lais Mara Siqueira dasc | de Jesus Guirro, Rinaldo Robertob
Affiliations: [a] Federal University of the Santa Catarina, Campus Araranguá-SC, Brazil | [b] Rehabilitation and Functional Performance Post-Graduate Program, Ribeirão Preto of the Medical School, University of São Paulo, Ribeirão Preto, Brazil | [c] Rehabilitation and Functional Performance Post-Graduate Program, Department of Biomechanics, Medicine and Rehabilitation of the Locomotor Apparatus, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, Brazil
Correspondence: [*] Corresponding author: Alexandre Márcio Marcolino, Rehabilitation and Functional Performance Post-Graduate Program, Department of Biomechanics, Medicine and Rehabilitation of the Locomotor Apparatus, Ribeirão Preto Medical School, University of São Paulo, Avenida Bandeirantes, 3900, Ribeirão Preto, São Paulo, CEP 14049-900, Brazil. E-mail:[email protected]
Abstract: PURPOSE: The purpose this study was perform a biomechanical evaluation to compare the influence of commercial models of different non-articular proximal forearm orthoses widths (2.5 cm, 5.5 cm, 7.5 cm and 12.0 cm) in the extensor muscle activation, range of motion and grip strength in healthy subjects. METHODS: Was analyzed data from extensor carpi radialis, extensor carpi ulnares and extensor digitorum comunis using surface electromyography, simultaneous with a wrist electrogoniometer MiotecTM and a hydraulic dynamometer JamarTM. The sequence of tests with all the commercial orthoses models was randomized. Statistics analyses were performed by linear model with mixed effects. RESULTS: According to our findings the non-articular proximal forearm orthoses (2.5 cm - narrowest) positioned close to lateral epicondyle provided lesser muscle activation on extensor carpi radialis brevis/longus and extensor digitorum comunis, decreased wrist extension and grip strength during submaximal grip task (p< 0.01). CONCLUSIONS: A narrow non-articular proximal forearm orthosis positioned close to the lateral epicondyle might decrease the extensor muscle activation and therefore could reduce mechanical stress on its insertion, based on this sample. Clinical studies must be conducted to confirm these findings.
Keywords: Orthoses, brace, lateral epicondylitis, electromyography, wrist biomechanics
DOI: 10.3233/BMR-160727
Journal: Journal of Back and Musculoskeletal Rehabilitation, vol. 30, no. 1, pp. 145-151, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]