Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Lee, Dong Gyu | Chang, Min Cheol*
Affiliations: Department of Physical Medicine and Rehabilitation, College of Medicine, Yeungnam University, Taegu, Korea
Correspondence: [*] Corresponding author: Min Cheol Chang, Department of Physical Medicine and Rehabilitation, College of
Abstract: BACKGROUND AND OBJECTIVE: We report the case of a patient who presented with right dorsal scapular neuropathy after a trigger point injection into the right rhomboid major muscle. Through a nerve conduction study and electromyography, we demonstrated dorsal scapular nerve injury in this patient. CASE REPORT: A 38-year-old man complained that his right shoulder functioned less optimally during push-up exercises after a trigger point injection 4 weeks prior. Physical examination revealed mildly reduced right shoulder retractor muscle strength compared with the left side. We performed a nerve conduction velocity test and electromyography 5 weeks after the injection. The compound muscle action potential of the right dorsal scapular nerve showed low amplitude (left vs. right side: 5.2 vs. 1.6 mV) and delayed latency (left vs. right side: 4.9 vs. 6.8 ms). Positive sharp wave (1+) and mildly reduced recruitment were seen on electromyography of the rhomboid major muscle. The findings of the nerve conduction velocity test and electromyography indicated partial right dorsal scapular neuropathy. The nerve injury seemed to have been caused by the needle inserted during trigger point injection. CONCLUSION: Clinicians should pay attention to the occurrence of dorsal scapular nerve injury when performing trigger point injection into the rhomboid muscle.
Keywords: Peripheral nerve injuries, myofascial pain syndromes, intramuscular injections, lidocaine, nerve conduction, electromyography
DOI: 10.3233/BMR-169740
Journal: Journal of Back and Musculoskeletal Rehabilitation, vol. 31, no. 1, pp. 211-214, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]