Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Hightower, C. Makena; | Yalcin, Ozlem | Salazar Vázquez, Beatriz Y.; | Johnson, Paul C. | Intaglietta, Marcos
Affiliations: Department of Bioengineering, University of California, San Diego, La Jolla, CA, USA | Faculty of Medicine, Universidad Juárez del Estado de Durango, Durango, México
Note: [] Address for correspondence: Dr. C. Makena Hightower, Department of Bioengineering, University of California, San Diego, La Jolla, CA 92093-0412, USA. Tel.: +1 858 543 2315; Fax: +1 858 822 4830; E-mail: [email protected].
Abstract: The effect of low and high viscosity hemodilution with plasma expanders on the extent of the cell free layer (CFL) width was analyzed in the microcirculation of the exteriorized cremaster muscle preparation of Sprague–Dawley male rats. Anesthetized animals were subjected to 40% hemodilution by blood volume, using 5% human serum albumin (HSA) or 6% Hetastarch (hydroxyethyl starch 670 kDa). Arterioles (n=5 for each treatment) were investigated. Mean arterial pressure, heart rate, vessel flow velocity and CFL width were measured at baseline and 5, 20 and 40 min post-exchange transfusion. Blood and plasma viscosity was determined from terminal blood collections. CFL width and pseudoshear rate, diameter and flow, normalized to baseline, were significantly elevated at all post-exchange assessments. Peripheral vascular resistance decreased. The increase of the CFL width was greater with HSA by comparison with Hetastarch hemodilution (p<0.05). Hetastarch blood and plasma viscosities increased significantly compared to those of HSA (p<0.05). This study shows that CFL widths are influenced by plasma expander viscosity, a phenomenon proportional to the increase in molecular weight of the colloids in solution.
Keywords: Hemodilution, plasma viscosity, microcirculation, shear stress
DOI: 10.3233/BIR-2011-0586
Journal: Biorheology, vol. 48, no. 2, pp. 115-125, 2011
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]