Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Eniwumide, Joshua O. | Lee, David A. | Bader, Dan L.
Affiliations: Medical Engineering Division and IRC in Biomedical Materials, School of Engineering and Materials Science, Queen Mary University of London, Mile End Road, London, UK
Note: [] Address for correspondence: Dr. Joshua Eniwumide, Marie Curie Research Fellow, Charité – Universitätsmedizin Berlin, Centrum für Muskuloskeletale Chirurgie, Forum 4 Psf 24, Augustenburger Platz 1, D-13353 Berlin, Germany. Tel.: +49 30 450 559087; Fax: +49 30 450 559969; E-mail: [email protected].
Abstract: Limitations to nutrient transport provide a challenge to the development of 3D tissue-engineered constructs. A heterogeneous distribution of viable cells and functional matrix within the developing tissue is a common consequence. In the present study, a bioreactor was developed to perfuse fluid through cylindrical agarose constructs. The transport and distribution of dextran molecules (FD-4, FD-500, FD-2000) within the agarose was visualized in order to determine the bioreactors effectiveness for transport enhancement. By 24 h, the perfusion bioreactor achieved 529%, 395% and 294% higher concentrations of FD-4, FD-500 and FD-2000, respectively, than those solely due to diffusion. Of particular interest was the effectiveness of the bioreactor to transport molecules to the central region of the constructs. In this respect, the perfusion bioreactor was found to increase transportation of FD-4, FD-500 and FD-2000 by 30%, 291% and 222% over that of diffusion. Articular chondrocytes were cultured and perfused using the bioreactor. The improved molecular transport achieved led to an average 75% and 1340% increase of DNA and sulphated GAG, respectively at 20 days. More significantly was the 106% and 1603% increase of DNA and GAG, respectively, achieved at the central core of the 3D constructs.
Keywords: Bioreactors, tissue engineering, molecular transport, fluid flow, perfusion chondrocytes
DOI: 10.3233/BIR-2009-0552
Journal: Biorheology, vol. 46, no. 5, pp. 417-437, 2009
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]