Authors: van Dam, Evelyne A. | Dams, Susanne D. | Peters, Gerrit W.M. | Rutten, Marcel C.M.; | Schurink, Geert Willem H. | Buth, Jaap | van de Vosse, Frans N.
Affiliations: Department of Biomedical Engineering, Technische Universiteit Eindhoven, The Netherlands | Department of Mechanical Engineering, Technische Universiteit Eindhoven, The Netherlands | Department of Vascular Surgery, University Hospital Maastricht, The Netherlands | Department of Vascular surgery, Catharina Hospital Eindhoven, The Netherlands
Note: [] Address for correspondence: Dr. M.C.M. Rutten, Department of Biomedical Engineering, Technische Universiteit Eindhoven, WH 4.120, PO Box 513, 5600 MB Eindhoven, The Netherlands. Tel.: +31 40 247 2789; Fax: +31 40 244 7355; E-mail: [email protected].
Abstract: The objective of this study is to determine whether the linear viscoelastic properties of an abdominal aortic aneurysm thrombus can be determined by rheometry. Although large strains occur in the in vivo situation, in this work only linear behavior is studied to show the applicability of the described methods. A thrombus exists of several layers that vary in composition, structure and mechanical properties. Two types of thrombus are described. In discrete transition thrombi the layers are not or at most weakly attached to each other and the structure of each layer is different. Continuous transition thrombi consist of strongly attached layers whose structure changes gradually throughout the thickness of the thrombus. Shear experiments are performed on samples from both types of thrombus on a rotational rheometer using a parallel plate geometry. In the discrete type the storage modulus G′ cannot be assumed equal for the different layers. In the continuous thrombus, G′, changes gradually throughout the layered structure. In both types the loss modulus, G″, does not vary throughout the thrombus. Furthermore, it was found that Time–Temperature Superposition is applicable to thrombus tissue. Since results were reproducible it can be concluded that the method we used to determine the viscoelastic properties is applicable to thrombus tissue.
Keywords: Mechanical properties, rheometry, intraluminal thrombus, Time–Temperature Superposition, storage modulus, loss modulus
Journal: Biorheology, vol. 43, no. 6, pp. 695-707, 2006
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]