Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: van Turnhout, Mark | Peters, Gerrit | Stekelenburg, Anke | Oomens, Cees;
Affiliations: Eindhoven University of Technology, Faculty of Biomedical Engineering, Department of Materials Technology, The Netherlands | Eindhoven University of Technology, Faculty of Mechanical Engineering, Department of Polymer Technology, The Netherlands
Note: [] Address for correspondence: Cees Oomens, Eindhoven University of Technology, Biomedical Engineering, Materials Technology, PO Box 513, WH 4.124, 5600 MB Eindhoven, The Netherlands. Tel.: +31 40 247 2818; Fax: +31 40 244 7355; E‐mail: [email protected].
Abstract: The objective of the current study was to determine the in vitro passive transverse mechanical properties of skeletal muscle with Dynamic Mechanical Thermal Analysis (DMTA) tests. The starting hypotheses was that the time–temperature‐superposition principle could be used to expand the DMTA results to a 1 kHz frequency range. Experiments were performed with rat hind leg skeletal muscle tissue samples on a rotational rheometer using a parallel plate geometry. Because of the small size and low modulus of the samples, the standard test geometry was altered and the samples were shifted from the center to the edge of the plates. From strain sweep tests it became clear that for strains smaller than 0.003 the muscle tissue behaves linearly. In the linear region storage moduli ranged between 24 kPa (ω=1 rad/s) and 42 kPa (ω=100 rad/s) at T=4°C and 22 kPa and 33 kPa at 29°C within the experimental frequency range. The loss modulus decreased with increasing frequency and ranged between 7 and 4 kPa at 4°C and 4.5 and 3.5 kPa at 29°C. Although the properties are clearly temperature dependent, a temperature shift in phase angle δ could not be detected, thus Time Temperature Superposition is not allowed for skeletal muscle in vitro.
Keywords: Viscoelastic, time–temperature‐superposition, impact frequencies, oscillatory shear, soft tissue, alternative geometry
Journal: Biorheology, vol. 42, no. 3, pp. 193-207, 2005
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]