Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Chen, D. | Kaul, D.K.
Affiliations: Department of Medicine, Division of Hematology, Albert Einstein College of Medicine, Bronx, NY 10461, USA
Abstract: The present study compares hematologic, rheologic and hemodynamic characteristics of red cells from mouse, rat and human. Red cells in these species are biconcave discs that show significant differences in diameter and mean corpuscular volume (MCV). However, differences in mean corpuscular hemoglobin concentration (MCHC) are not significant. Viscosity measurement of washed red cell suspensions (in each case the medium osmolarity adjusted to match plasma osmolarity) showed significant interspecies differences at shear rates of 37.5 and 750 sec−1 as follows: Human > rat > mouse. Hemodynamic and microcirculatory behavior of these red cells was investigated in the artificially perfused ex vivo mesocecum vasculature of the rat. Hemodynamic measurements in the whole ex vivo mesocecum preparation revealed maximal increase in the peripheral resistance unit (PRU) for the human red cells followed by the rat and mouse red cells, respectively, at a hematocrit (Hct) of 40%. Further, measurements of red cell velocities (Vrbc) in single arterioles of the mesocecum vasculature, during sustained perfusion with washed red cell suspensions, showed that at any given perfusion pressure (Pa), Vrbc for both mouse and rat red cells was higher than that for human red cells, while Vrbc for mouse red cells was higher than that for the rat. These results demonstrate that the microvascular flow behavior of these red cells is likely to be influenced by both physical and rheologic characteristics.
Keywords: Mammalian red cells, rheology, hemodynamics, ex vivo vasculature, peripheral resistance (PRU), red cell velocity (Vrbc)
DOI: 10.3233/BIR-1994-31109
Journal: Biorheology, vol. 31, no. 1, pp. 103-113, 1994
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]