Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Kim, Y.H. | Chandran, K.B.
Affiliations: Department of Biomedical Engineering, University of Iowa, Iowa City, IA 52245, USA
Abstract: A study using both experimental and numerical methods was conducted to determine flow dynamics in the vicinity of an end-to-end anastomosis. In vitro experiments were performed to determine the variations in the conduit cross-section at the anastomosis in specimens under static loading. The experimentally determined geometries were used to simulate steady flow through an end-to-end anastomosis using the finite analytic (FA) numerical solution technique in order to obtain solutions for the governing axisymmetric laminar flow equations. Wall shear stresses in the vicinity of end-to-end anastomoses under steady flow conditions were measured using a flush-mounted hot-film anemometer (FMHFA) probe. The experimental measurements were in agreement with numerical results, except in flow with low Reynolds numbers. Wall shear stresses increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stresses were observed distal to the anastomosis. The present study suggests a correlation between regions of low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia (ANFH) in end-to-end anastomoses.
Keywords: Vascular grafts, end-to-end anastomosis, compliance mismatch, wall shear stress, anastomotic neointimal fibrous hyperplasia
DOI: 10.3233/BIR-1993-30203
Journal: Biorheology, vol. 30, no. 2, pp. 117-130, 1993
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]