Article type: Research Article
Authors: Müller, G.H.a | Schmid-Schönbein, H.a | Meiselman, H.J.b
Affiliations: [a] Department of Physiology, Rheinisch-Westfälische Technische Hochschule, 5100 Aachen, Germany | [b] Department of Physiology and Biophysics, USC School of Medicine, Los Angeles, CA 90033, USA
Note: [] Accepted by: Editor P. Gaehtgens
Abstract: Several previous studies have shown that exposure of RBC to temperatures in the range 47 to 48.8°C causes an irreversible alteration of RBC rheological properties; membrane elasticity and viscosity are both increased and greater pressure is required for RBC entry into pipettes. While it has been tacitly assumed that these rheologic alterations are membrane specific, no data on heat-treated hemoglobin (Hb) solutions appear to exist. The present study was thus designed to evaluate the effects of heat-treatment (48.8 ± 0.1°C, 3 to 20 min) on the viscoelasticity of Hb solutions (30 to 45 g/100 ml) prepared from normal human RBC. Measurements of the viscous component (VC) and elastic component (BC) were made at 25°C using Couette (GDM) and capillary (OCR-D) rheometers; shear rates ranged from 1 to 200 s−1. All unheated Hb solutions were Newtonian and did not exhibit elasticity. However, after 3 min of heating, an elastic component was measurable. Both VC and EC increased with heating time in a power law fashion. VC continued to exhibit Newtonian behavior, whereas the magnitude of EC was an inverse function of shear rate and directly related to Hb concentration and treatment time. A relaxation function applied to our data suggests a first order reaction. These results indicate that both cytoplasmic and membrane viscoelasticity should be considered in order to fully comprehend the rheologic behavior of heat-treated RBC.
Keywords: Heat-treatment, hemoglobin solutions, viscoelasticity, gelation
DOI: 10.3233/BIR-1992-292-302
Journal: Biorheology, vol. 29, no. 2-3, pp. 203-216, 1992
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]