Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Arai, Koichia | Iino, Masaakia | Shio, Hideob | Uyesakat, Nobuhiroa; *
Affiliations: [a] Department of Physiology, Nippon Medical School, Bunkyo-ku, Tokyo, 113, Japan | [b] Department of Neurology, Faculty of Medicine, Kyoto University, Sakyo-ku, Kyoto, 606, Japan
Correspondence: [*] Correspondence to: N. Uyesaka, Department of Physiology, Nippon Medical School, Sendagi, 1-1-5, Bunkyo-ku, Tokyo, 113 Japan
Note: [] Accepted by: Editor E. Fukada
Abstract: Although the filtration method has been widely employed in red cell deformability studies, the structural irregularity of the pores of a Nuclepore polycarbonate membrane has always been a major problem. Anegawa, T. et al. (Clin. Hemorheol., 7, 1987) obtained a higher reproducibility with the filtration method using a newly designed thin metal film with pores engraved by the photofabrication technique. We further studied the pressure - flow rate relationship of red cell suspension employing this nickel mesh. The filtration of red cell suspensions through the nickel mesh was not influenced by leukocytes contamination or added leukocytes up to a leukocyte count of 250 cells/mm3 within an experimental limitation. On the other hand, the flow was greatly influenced by leukocytes contamination when the polycarbonate membrane was used. The nickel mesh was found to be useful in detecting major determinants of red cell deformability, such as cell geometry and internal cellular viscosity, and in detecting abnormalities of red cell deformability in a patient with microangiopathic hemolytic anemia. In conclusion, the present study clearly shows that the nickel mesh is preferable for investigating red cell deformability to the polycarbonate membrane from a quantitative point of view. This material should contribute to the physiologic and clinical investigation of red cell deformability.
Keywords: Red Cell Deformability, Nickel Mesh, Pressure-Flow Rate Relationship, Leukocyte, Microangiopathic Hemolytic Anemia
DOI: 10.3233/BIR-1990-27105
Journal: Biorheology, vol. 27, no. 1, pp. 47-65, 1990
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]