Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Powell, Elizabeth Salmona | Carrico, Cheryla | Raithatha, Ravib | Salyers, Emilya | Ward, Andreaa | Sawaki, Lumya; c; *
Affiliations: [a] University of Kentucky, Department of Physical Medicine and Rehabilitation, Lexington, KY, USA | [b] University of Pikeville Kentucky College of Medicine, Pikeville, KY, USA | [c] HealthSouth Cardinal Hill Rehabilitation Hospital, Lexington, KY, USA
Correspondence: [*] Address for correspondence: Lumy Sawaki, MD, PhD, University of Kentucky, Department of Physical Medicine and Rehabilitation at HealthSouth Cardinal Hill Hospital, 2050 Versailles Road, Lexington, KY 40504, USA. Tel.: +1 859 323 6226; Fax: +1 859 323 1123; E-mail: [email protected].
Abstract: STUDY DESIGN:This double-blind, sham-controlled, crossover case study combined transvertebral direct current stimulation (tvDCS) and locomotor training on a robot-assisted gait orthosis (LT-RGO). OBJECTIVE:Determine whether cathodal tvDCS paired with LT-RGO leads to greater changes in function and neuroplasticity than sham tvDCS paired with LT-RGO. SETTING:University of Kentucky (UK) HealthCare Stroke and Spinal Cord Neurorehabilitation Research at HealthSouth Cardinal Hill Hospital. METHODS:A single subject with motor incomplete spinal cord injury (SCI) participated in 24 sessions of sham tvDCS paired with LT-RGO before crossover to 24 sessions of cathodal tvDCS paired with LT-RGO. Functional outcomes were measured with 10 Meter Walk Test (10MWT), 6 Minute Walk Test (6MWT), Spinal Cord Independence Measure-III (SCIM-III) mobility component, lower extremity manual muscle test (MMT), and Berg Balance Scale (BBS). Corticospinal changes were assessed using transcranial magnetic stimulation. RESULTS:Improvement in 10MWT speed, SCIM-III mobility component, and BBS occurred with both conditions. 6MWT worsened after sham tvDCS and improved after cathodal tvDCS. MMT scores for both lower extremities improved following sham tvDCS but decreased following cathodal tvDCS. Corticospinal excitability increased following cathodal tvDCS but not sham tvDCS. CONCLUSION:These results suggest that combining cathodal tvDCS and LT-RGO may improve functional outcomes, increase corticospinal excitability, and possibly decrease spasticity. Randomized controlled trials are needed to confirm these conclusions. SPONSORSHIP:This publication was supported by the National Center for Research Resources and the National Center for Advancing Translational Sciences, National Institutes of Health, through Grant UL1TR000117, and the HealthSouth Cardinal Hill Stroke and Spinal Cord Endowment (1215375670).
Keywords: Neuromodulation, neuroplasticity, transcutaneous spinal direct current stimulation, motor function, lower extremity, treadmill training
DOI: 10.3233/NRE-151292
Journal: NeuroRehabilitation, vol. 38, no. 1, pp. 27-35, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]