Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Subtitle:
Article type: Research Article
Authors: Hohloch, Lisa | Konstantinidis, Lukas | Wagner, Ferdinand C. | Strohm, Peter C. | Südkamp and, Norbert P. | Reising, Kilian*
Affiliations: Department of Surgery, Clinic for Orthopedic and Trauma Surgery, Freiburg University Hospital, Freiburg, Germany
Correspondence: [*] Corresponding author: Kilian Reising, Department of Surgery, Clinic for Orthopedic and Trauma Surgery, Freiburg University Hospital, Hugstetter Str. 55, D-79106 Freiburg, Germany. Tel.: +49 76127024010; Fax: +49 76127028571; E-mail:[email protected]
Abstract: BACKGROUND: Closed reduction and percutaneous pinning is regarded as the treatment of choice for unstable supracondylar humerus fractures, but there are cases in which the use of external fixation is preferable. OBJECTIVE: The aim of this study was to investigate whether the method of external fixation could be considered as a stable alternative to percutaneous pinning and whether there was a difference in stability between two different external fixator constructs. METHODS: Eighteen synthetic humeri were allocated to three groups of six bones each. The specimens of group 1 were fixed by crossed pinning, those of group 2 by a new variation of an external fixator and the specimens of group 3 by an established variation of it. Osteotomy displacement was measured under static loading in internal and external rotation, as well as in extension and flexion. RESULTS: The external fixators proved to be significantly more stable than crossed pinning in sagittal loading. In internal rotation loading the new variation of the external fixator showed the best results. CONCLUSIONS: In case of fractures that can't be replaced by closed reduction the new variation of external fixator should be preferred to the established variation or open reduction and crossed pinning.
Keywords: Supracondylar fracture, pediatric, biomechanical, crossed pinning, external fixator
DOI: 10.3233/THC-150905
Journal: Technology and Health Care, vol. 23, no. 4, pp. 453-461, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]