Issue title: 3rd European Conference on Engineering and Medicine
Article type: Research Article
Authors: Camevali, P. | Ferrigno, G.; * | Aliverti, A. | Pedotti, A.
Affiliations: Centro di Bioingegneria, Politecnico di Milano, Fondazione Pro Juventute Don Gnocchi, Milan, Italy
Correspondence: [*] Correspondence: Giancarlo Ferrigno, Centro di Bioingegneria, Via Gozzadini 7, 20148 Milano, Italy, Tel.: +39-2-40308283, Fax: +39-2-26861144
Abstract: A method for kinematic analysis of chest wall motion is presented, based on a TV-image processor which allows a three-dimensional assessment of volume change of the trunk by automatically computing the co-ordinates of several passive markers placed on relevant landmarks of the thorax and abdomen. The parallel computation used for the image processing allows a real time recognition of the passive markers with the necessary accuracy. A geometric model also allows the on-line computation of the contribution to the chest volume by the different parts. For this purpose the model is based on 96 tetrahedrons which can be grouped into 16 compartments and into four sections representing: upper thorax (reflecting the action of neck and parasternal muscles and the effect of pleural pressure), lower thorax (reflecting the action of diaphragm and the effect of pleural and abdominal pressure), upper and lower abdomen (reflecting the actions of diaphragm and abdominal muscles). The volume can also be split into two vertical sections pointing out asymmetries between the right and left side. The method is non-invasive, non-ionizing and leaves the subject maximum freedom of movement during the test, thus being suitable for routine clinical analysis. The monitoring of the subject can be prolonged in time and can be performed in different postures: standing, sitting, supine and lying on one side. The method was tested on eight healthy subjects showing good accuracy, reliability and reproducibility.
Keywords: Chest motion analysis, optical pletismography, 3D movement analysis
DOI: 10.3233/THC-1996-4107
Journal: Technology and Health Care, vol. 4, no. 1, pp. 43-65, 1996
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]