Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Högstedt, P.a; b; * | Kadefors, R.a; b | Näslund, P.-E.c
Affiliations: [a] Lindholmen Development, PO Box 8714, S-402 75 Gothenburg, Sweden | [b] Chalmers University of Technology, Gothenburg, Sweden | [c] The Occupational Health Clinic, Första Långgatan 22, Gothenburg, Sweden
Correspondence: [*] Corresponding author. Email: [email protected].
Abstract: Magnetopneumography (MPG) is a non-invasive technique to measure the amount of magnetizable dust retained in the lung. This study concerns the relation between MPG measurements of welding fume dust retention in the human lung on the one hand and chest radiography and crude counting of exposure time on the other. Precision and accuracy of the MPG instrument was found to be high. A weak but statistically significant correlation (r=0.45, P<0.05) was found between exposure time and retention of magnetizable material in a group of 112 full time manual metal arc welders. The variability was high. Retention rate was estimated on a group level. Chest radiographs of 23 arc welders were reviewed separately in random order by two independent readers who were not aware of MPG findings, occupational anamnesis or the subject's identity and age. No statistically significant correlation was found between MPG and the observer's grading. A weak but statistically significant correlation was found between the readers. We conclude that MPG is highly sensitive to retention of magnetizable material retained in the lung and that the correlation between radiography and MPG reported by previous workers could not be verified in this study. The divergent results may well be due to methodological differences. Investigations using more specific roentgenological methods, such as high resolution computed tomography (HRCT), should be performed.
Keywords: Lung, Chest radiography, Magnetopneumography, Welding, Dust retention
DOI: 10.3233/THC-1995-3104
Journal: Technology and Health Care, vol. 3, no. 1, pp. 15-21, 1995
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]