Article type: Research Article
Authors: Milovanovic, Aleksandara | Isailovic, Veliborb; c | Saveljic, Igora; c | Filipovic, Nenadb; c; *
Affiliations: [a] Institute for Information Technologies, University of Kragujevac, Kragujevac, Serbia | [b] Faculty of Engineering, University of Kragujevac, Kragujevac, Serbia | [c] Bioengineering Research and Development Center, Kragujevac, Serbia
Correspondence: [*] Corresponding author: Nenad Filipovic, Faculty of Engineering, University of Kragujevac, Kragujevac, Serbia. E-mail: [email protected].
Abstract: BACKGROUND: Fractional flow reserve (FFR) determined invasively has been globally accepted as the gold standard for determining the functional significance of coronary artery stenoses. However, despite its great importance, the invasive method has certain disadvantages, including the risk of vascular injuries, the need for vasodilation, and significant medical costs. That is why great attention was paid to the development of non-invasive methods that would enable reliable diagnosis without exposing patients to the risk of unwanted consequences. OBJECTIVE: This paper aimed to create and verify an alternative, less resource- and time-demanding, non-invasive solution. METHODS: The determination of FFR is based on the application of the fundamental laws of fluid dynamics. All energy losses in the coronary artery with stenosis were identified and analyzed in detail. A three-dimensional model of a coronary artery was generated using the corresponding angiographic images. Finally, the pressure due to stenosis was calculated and the FFR was determined. RESULTS: The results obtained using the proposed analytical method were compared with available experimental data for 40 patients who experienced the invasive coronary angiography. The coefficient of determination, mean difference and standard deviation values are determined to be 0.726, -0.017 and 0.056, respectively. These values were slightly higher for FFR values above 0.80. CONCLUSION: The FFR calculated by the proposed analytical method has a relatively good correlation with clinical data, which leads to the conclusion that it can provide a reliable assessment of the functional significance of coronary stenosis.
Keywords: Coronary artery stenosis, analytical method, fractional flow reserve
DOI: 10.3233/THC-240803
Journal: Technology and Health Care, vol. 32, no. 6, pp. 4613-4626, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]