Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: R, Seethalakshmia | S, Hariharanb | Karnan, Hemalathab; * | V, Keerthanab | V, Aksharab
Affiliations: [a] School of Arts Sciences, Humanities and Education, SASTRA Deemed University, Thanjavur, Tamil Nadu, India | [b] School of Chemical and Biotechnology, SASTRA Deemed University, Thanjavur, Tamil Nadu, India
Correspondence: [*] Corresponding author: Hemalatha Karnan, School of Chemical and Biotechnology, SASTRA Deemed University, Thanjavur, Tamil Nadu, India. E-mail: [email protected].
Abstract: BACKGROUND: Atherosclerosis is a condition which disrupts blood flow due to plaque build-up inside the arteries. Under conditions where consecutive plaques are prevailing blood hammer principle is exhibited. OBJECTIVE: The pressure and shear stress produced at an infinitesimal area act as the governing equation for stent modeling. The leading order pressure lays the foundation for the design of cardiac stents with definite dimensions. METHOD: The designed stent was encapsulated inside a crimper validated through ANSYS-static and transient structural simulation to derive the total deformation, equivalent strain, and stress exerted on the stent. Five different biomaterials stainless steel 316, cobalt, chromium, platinum, and Poly lactic acid were selected for the material assessment. RESULT: Static and Transient structural analysis for a period of 1 and 10 secs was implemented for a stent with and without a crimper. The material performance in terms of total deformation, equivalent stress, and strain are analyzed. CONCLUSION: The paper envisions the dynamics of blood hammer in atherosclerosis that provides the changes in the pressure and clotting process. It shows the promising results of the stent behavior in varied forces which gives valuable insights for future improvement in stent design and material selection.
Keywords: Atherosclerosis, blood hammer, stent, transient
DOI: 10.3233/THC-240051
Journal: Technology and Health Care, vol. 32, no. 6, pp. 4223-4238, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]