Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Special Section: Future Arthroplasty
Guest editors: Mustafa Citak
Article type: Research Article
Authors: Incesoy, Mustafa Alpera | Yildiz, Fatiha; * | Pulatkan, Mehmet Anila | Yesiller, Omer Faruka | Toluk, Ozlemb | Erdem, Ahmet Cana | Tuncay, Ibrahima
Affiliations: [a] Department of Orthopedics, Faculty of Medicine, Bezmialem Vakif University, Istanbul, Turkey | [b] Department of Biostatistics, Faculty of Medicine, Bezmialem Vakif University, Istanbul, Turkey
Correspondence: [*] Corresponding author: Fatih Yildiz, Department of Orthopedics, Faculty of Medicine, Bezmialem Vakif University, Istanbul, Turkey. E-mail: [email protected].
Abstract: BACKGROUND: With the restoration of the natural hip biomechanics, a successful total hip arthroplasty (THA) and long-term survival is pursued. Although robotic THA (rTHA) has been developed to increase accuracy of implant positioning, leg lengths and offsets, discussions about its radiological and clinical advantages over conventional THA (cTHA) continues. OBJECTIVE: The aim of this study was to compare clinical and radiological outcomes of robotic and conventional THA. METHODS: This retrospective study compares functional and radiological outcomes of 82 rTHA with a matched group of 82 cTHA in terms of age, sex, body mass index and preoperative functional scores. The minimum follow up was 12 months for all patients. Functional outcomes were Harris Hip Score (HHS) and the Western Ontario and McMaster University Osteoarthritis index (WOMAC) evaluated pre- and postoperatively. Radiological evaluations included position of cup placement according to Lewinnek and Callanan safe zones, Canal Fill Ratio (CFR), Leg Length Discrepancy (LLD), Lateral offset (LO) and Femoral Component Alignment (FCA). Complications were also evaluated. RESULTS: In the rTHA group, 91.5% (75 out of 82) of the acetabular cups were positioned within the safe zone whereas it was 63.4% (52 out of 82) for the cTHA group (p< 0.001). According to Callanan, they were 84.1% and 50%, respectively (p< 0.001). Between the groups, no statistically significant difference was found in CFR, LLD, HO, FCA, AI, AA, WOMAC, HHS and major complication rates. CONCLUSION: rTHA is superior to cTHA in terms of accuracy and reproducibility of the cup placement, however no apparent clinical benefit was found in short term follow.
Keywords: Total hip arthroplasty, robot-assisted surgery, component positioning, robotic total hip replacement
DOI: 10.3233/THC-231111
Journal: Technology and Health Care, vol. 32, no. 5, pp. 3681-3691, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]