Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Wu, Zhi-Ping | Yin, Jian-Lin | Liu, Shan-Kai | Ji, Song | Liu, Jian-Yu | Wang, Hai-Lan | Zhang, Yi-Sheng | Zhang, Da-Zhong*
Affiliations: Department of Interventional Radiology, Taizhou People’s Hospital, Taizhou, Jiangsu, China
Correspondence: [*] Corresponding author: Da-Zhong Zhang, Department of Interventional Radiology, Taizhou People’s Hospital, No. 366 Taihu Road, Medical High-tech District, Taizhou, Jiangsu 225300, China. E-mail: [email protected].
Abstract: BACKGROUND: The microsurgical treatment of paraclinoid aneurysms can be challenging due to the anatomical structures that surround them. OBJECTIVE: This study compared the clinical and angiographic outcomes of unruptured paraclinoid aneurysms treated with enterprise (EP) stents and low-profile visualized intraluminal support (LVIS) stents. METHODS: A retrospective analysis of the clinical and radiological data from 133 patients with 139 unruptured paraclinoid aneurysms, who received an EP or an LVIS stent between January 2017 and June 2021 at Taizhou People’s Hospital, was performed. Immediate postoperative and follow-up angiographic results were analyzed retrospectively using the Raymond-Roy occlusion classification (RROC). Any complications following the procedure and the patients’ clinical outcomes were noted. RESULTS: Enterprise stents were used for stent-assisted coiling in 64 patients with 68 aneurysms and LVIS stents were used in 69 patients with 71 aneurysms. Both groups exhibited an increase in the proportion of aneurysms meeting the criteria for RROC class I, but the LVIS group demonstrated a higher rate of aneurysms meeting the class I criteria compared with the EP group, both on immediate postoperative angiography (45.1% vs. 11.8%, p< 0.001) and on follow-up angiography (94.9% vs. 80.6%, p= 0.025). Procedure-related complications were experienced by 9.4% of patients in the EP group (one coil prolapse, two parent artery occlusions, and three thromboembolic events), and 8.7% of patients in the LVIS group (three stent-related thrombosis and three thromboembolic events). There were no statistically significant differences between the two groups in relation to perioperative complications (p= 0.746) or favorable clinical outcomes (p= 0.492). CONCLUSION: A greater proportion of aneurysms in the LVIS group met the criteria for RROC class I compared with the EP group. There is no significant difference in procedural complications or clinical outcomes between EP and LVIS stents. Although no aneurysm recurrence was observed during the short follow-up period, continued monitoring is required.
Keywords: Paraclinoid aneurysm, enterprise stent, LVIS stent, stent-assisted coiling
DOI: 10.3233/THC-220697
Journal: Technology and Health Care, vol. 31, no. 5, pp. 1855-1865, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]