Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Chen, Hongbinga | Su, Tongb | Wang, Qia | Zheng, Zhea | Li, Hongweic | Li, Jianboa; *
Affiliations: [a] Department of Forensic Medicine, Faculty of Basic Medical Sciences, Chongqing Medical University, Chongqing, China | [b] Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China | [c] Technical Department of Interpol Corps of the Chongqing Public Bureau, Chongqing, China
Correspondence: [*] Corresponding author: Jianbo Li, Department of Forensic Medicine, College of Basic Medicine, Chongqing Medical University, Chongqing 400016, China. E-mail: [email protected].
Abstract: BACKGROUND: Aneurysms are associated with a mortality rate of 81% or more in cases of rupture. Intraluminal thrombus (ILT) is a common complication of aneurysms, it can greatly increase the risk of rupture. Especially for some of the more complex aneurysms, physicians need to consider the risk of thrombosis or progression and precisely formulate a treatment plan. Therefore, it is particularly important to assess the level of thrombosis risk through haemodynamics. OBJECTIVE: To analyse the haemodynamic indices and compare the thrombosis risk in a double false lumen abdominal aortic dissection aneurysm using computational fluid dynamics (CFD). METHODS: Computer tomography angiography (CTA) imaging data were collected from a patient with a double false lumen abdominal aortic dissection aneurysm, and three different lesion morphology aneurysm models were established, double false lumen abdominal aortic dissection aneurysm, single false lumen abdominal aortic dissection aneurysm and saccular abdominal aortic aneurysm, in order to analyse the flow velocity, time-averaged shear stress (TAWSS), oscillatory shear index (OSI), relative residence time (RRT) of blood flow, and endothelial cell activation potential (ECAP). RESULTS: All three aneurysms were in a low-flow state within the body, and the low-flow velocity flow in the proximal vessel wall extended to the right common iliac artery; the vortex intensity was more intense in the abdominal aortic dissection aneurysm than in the saccular abdominal aortic aneurysm. The risk area for thrombosis was concentrated in the expansion part of the aneurysm and the false lumen. The RRT and ECAP maxima of the double false lumen abdominal aortic dissection aneurysm were much greater than those of the single false lumen dissection aneurysm and saccular aortic aneurysm. CONCLUSION: Low-velocity blood flow, high OSI, low TAWSS, high RRT, and high ECAP regions correlate with the risk of thrombosis. The double false lumen type of abdominal aortic dissection aneurysm had some specificity in this case. The risk of thrombosis in the patient was extremely high, and the largest risk zone was within the smaller false lumen, which could be because the smaller false lumen was connected to the true lumen by only one breach. The results of the study provide some guidance in the early screening and development of treatment plans.
Keywords: Abdominal aortic dissection aneurysm, CTA, computational fluid dynamics (CFD), thrombosis risk, patient-specific simulation
DOI: 10.3233/THC-220481
Journal: Technology and Health Care, vol. 31, no. 3, pp. 1003-1015, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]