Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Duan, Liana; 1 | Dang, Guangfua; 1 | Ge, Jinlingb; 1 | Gao, Yanga | Wang, Lihuac; *
Affiliations: [a] Department of Ophthalmology, First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Jinan, Shandong, China | [b] Department of Ophthalmology, Jinan Mingshui Eye Hospital, Jinan, Shandong, China | [c] Department of Ophthalmology, Shandong Provincial Hospital Affiliated to Shandong University, Jinan, Shandong, China
Correspondence: [*] Corresponding author: Lihua Wang, Department of Ophthalmology, Shandong Provincial Hospital Affiliated to Shandong University, No. 324 Jingwuweiqi Road, Jinan, Shandong 250012, China. E-mail: [email protected].
Note: [1] These authors contributed equally to this work.
Abstract: BACKGROUND: Aspheric intraocular lens (IOLs) implantation has been widely applied in cataract surgery. However, there is no consensus on the optimal guidance for the operations in IOLs implantation. OBJECTIVE: This study evaluated the visual function of Chinese cataract patients six months after cataract surgery with two different guiding ideologies. METHODS: We evaluated 50 patients (61 eyes) with implantation of different aspheric IOLs (SN60WF IOLs, ZCB00 IOLs, PY-60AD IOLs, AO IOLs) 6 months after cataract surgery. Twenty-four patients (30 eyes) under individual implantation were ascribed to group 1 and 26 patients (31 eyes) with randomized implantation were ascribed to the control group (group 2). Postoperatively parameters included monocular best-corrected visual acuity (BCVA), contrast sensitivity (CS), total spherical aberration Z (4, 0) at 5 mm pupil size, and patient satisfaction. The quality of life after operation was assessed through the National Eye Institute Visual Function Questionnaire-25 (NEI VFQ-25). RESULTS: Six months after cataract operation, the contrast sensitivity with glare of group 1 at 2.5∘ was 0.697 ± 0.027, and 0.532 ± 0.049 in group 2. Besides, there was no significant difference at any other special frequency. The mean spherical aberration Z (4, 0) at 5 mm pupil size in group 1 was 0.015 ± 0.028 um, and in group 2 was 0.043 ± 0.109 um, with a significant difference (p< 0.01). The mean scores obtained from NEI VFQ-25 were not significantly different. CONCLUSION: It is effective to implant aspheric IOLs individually according to preoperative corneal spherical aberration. Patients obtained better contrast sensitivity with glare at 2.5∘, but there was no significant difference in BCVA, contrast sensitivity at other special frequency, and subjective visual function.
Keywords: Visual function, cataract, aspheric intraocular lens implantation, best-corrected visual acuity, contrast sensitivity
DOI: 10.3233/THC-220154
Journal: Technology and Health Care, vol. 31, no. 3, pp. 831-839, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]