Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Short Communication
Authors: Owida, Hamza Abua | Al-Nabulsi, Jamala; * | Ma’touq, Jumanab | Al-Naami, Bassamc | Alnaimat, Ferasa
Affiliations: [a] Medical Engineering Department, Faculty of Engineering, Al-Ahliyya Amman University, Amman, Jordan | [b] Department of Biomedical Engineering, School of Applied Medical Sciences, German Jordanian University, Amman, Jordan | [c] Department of Biomedical Engineering, Faculty of Engineering, The Hashemite University, Zarqa, Jordan
Correspondence: [*] Corresponding author: Jamal Al-Nabulsi, Medical Engineering Department, Faculty of Engineering, Al-Ahliyya Amman University, 19328 Amman, Jordan. E-mail: [email protected].
Abstract: BACKGROUND: Drawing blood from the fingertips for glucose testing is painful and likely to cause tissue damage over time. Earlobes are an alternative site for glucose measurement. OBJECTIVE: This work aims to validate the earlobe as an alternate test site for blood glucose testing by demonstrating valid and reliable statistically significant differences between the earlobes and standard reference sites. METHODS: Blood glucose concentrations from 50 volunteers were measured and statistically analysed from the reference sites (forearm and fingertip) and earlobe. The analysis included: 1) one-way analysis of variance (ANOVA), 2) regression analysis, 3) Bland Altman analysis, and 4) Clarke Error Grid analysis. RESULTS: The results indicated that there is no statistically significant difference between the three blood glucose-testing methods. For the forearm-earlobe and fingertip-earlobe, all measurements were grouped around the mean of 3.7 ± 1.96 SD and 2.96± 1.96 SD, respectively. Error grid analysis showed > 97% of all earlobe and references measurements fell in Zones A and B and were in the clinically acceptable level. CONCLUSIONS: The results have shown that the earlobe is a valid substitute for blood glucose measurements.
Keywords: Blood glucose testing, earlobe, fingertip, forearm, descriptive statistical analyses
DOI: 10.3233/THC-220033
Journal: Technology and Health Care, vol. 30, no. 6, pp. 1535-1541, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]