Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Sadasivam, S.* | V, Thulasi Bai
Affiliations: Department of Electronics and Communication Engineering, KCG College of Technology, Chennai, India
Correspondence: [*] Corresponding author: S. Sadasivam, Department of Electronics and Communication Engineering, KCG College of Technology, Chennai, India. E-mail: [email protected].
Abstract: BACKGROUND: Antennas for the microwave imaging system are large which results in higher radiation, manufacturing cost, poor radiation characteristics and it will be difficult to locate on breast tissues. OBJECTIVE: We propose a wearable ultra-wide band antenna for use in the diagnosis of breast cancer bio-medical applications. METHODS: The antenna has been fabricated on 1.6 mm FR4 substrate with a dimension of 28 × 14.4 mm2 and can operate between 2 GHz–12 GHz with S11<-10 dB with best radiation characteristics. The prototype of the proposed antenna was fabricated and practically tested and the results were found to be consistent with the simulated results. The proposed UWB antenna is intended to radiate and receive information covering the entire spectrum from 3 GHz to 13 GHz. For good impendence matching throughout the larger spectrum, the defected ground structure (diamond shape) was exploited. All the dimensions of the proposed design are confirmed by parametric study and optimization. RESULTS: The maximum simulated efficiency was ranging from 80 to 84% in the desired operating frequency. The maximum Specific Absorption Rate of the proposed antenna was 0.98 W/Kg. Therefore, the proposed UWB antenna could be the right structure for breast cancer diagnosis in terms of SAR. The antenna was found to have a substantial radiation efficiency of around 78%–84% in the desired operating bandwidth. The overall realized gain of the proposed UWB antenna was seen ranging from 1.8–4.2 dB which is sufficient for bio-medical applications. CONCLUSION: The breast phantom was modeled for the validation of the performance of the antenna and SAR was analyzed. The value of SAR of the designed antenna was observed at about 0.98 W/Kg, which is suitable for medical applications.
Keywords: Antenna, breast tumor, medical, radiation pattern, SAR
DOI: 10.3233/THC-220030
Journal: Technology and Health Care, vol. 31, no. 1, pp. 57-68, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]