Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Wang, Lana | Wu, Yanqib | Zhu, Minb; * | Zhao, Cuiliana; *
Affiliations: [a] Shanghai Key Laboratory of Intelligent Manufacturing and Robotics, School of Mechatronic Engineering and Automation, Shanghai University, Shanghai, China | [b] Department of Oral and Craniofacial Surgery, Shanghai Ninth People’s Hospital, College of Stomatology, Shanghai JiaoTong University of Medicine, National Center of Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai, China
Correspondence: [*] Corresponding authors: Min Zhu, Department of Oral and Craniofacial Surgery, Shanghai Ninth People’s Hospital, College of Stomatology, Shanghai JiaoTong University of Medicine, National Center of Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai, China. E-mail: [email protected]. Cuilian Zhao, Shanghai Key Laboratory of Intelligent Manufacturing and Robotics, School of Mechatronic Engineering and Automation, Shanghai University, Shanghai, China. E-mail: [email protected].
Abstract: BACKGROUND: Lip incompetence resulting from mouth breathing is a common clinical manifestation, while there are no definite indicators of amplitude and intensity of muscle functional training in clinical practice, which leads to unsatisfactory training results. OBJECTIVE: The aim was to quantify the relationship between electromyography (EMG) and force in orbicularis oris muscle, so that the indicators of muscle functional training can be evaluated using EMG signals, so as to improve the training effects. METHODS: The EMG and the force signals of orbicularis oris muscle from 0% to 100% MVC within 5 s in twelve healthy subjects (six males and six females; age, 25 ± 2 years; mass, 60 ± 15 kg) were recorded simultaneously for three trials. Four EMG features consisting of RMS, WAMP, SampEn and FuzzyEn were analyzed. The regression analyses were performed using first-order and third-order polynomial model. RESULTS: There were high correlations between the four EMG features and muscle force with the two models. The third-order model yielded a higher coefficient of determination (R2) than the linear model (p< 0.001) and the result of FuzzyEn (R2: 0.884 ± 0.059) was the highest in the four features. CONCLUSION: The third-order model with FuzzyEn of EMG signals may be used to guide the muscle functional training.
Keywords: Orbicularis oris muscle, surface electromyography, muscle force, FuzzyEn
DOI: 10.3233/THC-213545
Journal: Technology and Health Care, vol. 31, no. 1, pp. 47-56, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]