Article type: Research Article
Authors: Xu, Lina; 1 | Liu, Chunhuab; 1 | Ning, Xua | Bai, Zelinga | Qin, Mingxina | Guo, Haitaoc; * | Sun, Jiana; *
Affiliations: [a] College of Biomedical Engineering, Army Medical University, Chongqing, China | [b] Department of Human Resource, Army Medical University, Chongqing, China | [c] Department of Equipment, Southwest Hospital, Chongqing, China
Correspondence: [*] Corresponding authors: Haitao Guo, Department of Equipment, Southwest Hospital, Chongqing, 400037, China. E-mail: [email protected]. Jian Sun, College of Biomedical Engineering, Army Medical University, Chongqing, 400030, China. E-mail: [email protected].
Note: [1] The authors contributed equally to this work.
Abstract: BACKGROUND: Real-time clinical monitoring of cerebral edema (CE) is of great importance and requires continuously improved and optimized measurement hardware. METHODS: A new excitation source with higher frequency stability and wide output power range is presented in this work. The proposed excitation source is small in size and easy to integrate. The output power range of excitation signal used is 1.5 ∼ 33 dBm with a reference signal of 9 ∼ 11 dBm, and the phase shift stability of the excitation signal and reference signal reach 10-7 within 20 min. RESULTS: When normal saline (0.9%, 10 mL, 20 mL, 30 mL, 40 mL, and 50 mL) is injected into a human head phantom model, the magnetic induction phase shift (MIPS) changes from 252.78 ± 7.61 degrees to 252.40 ± 7.77 degrees. The MIPS signal shows a downward trend with increasing volume, indicating that MIPS can reflect the volume change of the measured object. Moreover, a more dramatic trend is visible when the solution volume increases from 0 to 10 mL and from 40 to 50 mL. This occurs where the volume increment is closer to the upper and lower sides of the over-ear sensor, where the magnetic field is strongest. CONCLUSION: The phantom simulation experiments illustrate that the proposed MIPS detection system based on a signal source can detect the real-time progress of CE. Advantages of low cost, high precision, and high sensitivity endow this system with excellent application prospects.
Keywords: Excitation source, cerebral edema, phase shift, magnetic induction
DOI: 10.3233/THC-192068
Journal: Technology and Health Care, vol. 29, no. 1, pp. 111-120, 2021
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]