Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Khamis, Sam
Affiliations: Gait and Motion Analysis Laboratory, Department of Pediatric Orthopaedics, Dana Children’s Hospital, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel | Tel.: +972 50 5452699; Fax: +972 3 6947280; E-mail: [email protected]
Correspondence: [*] Corresponding author: Gait and Motion Analysis Laboratory, Department of Pediatric Orthopaedics, Dana Children’s Hospital, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel. Tel.: +972 50 5452699; Fax: +972 3 6947280; E-mail: [email protected].
Abstract: BACKGROUND: Even though the importance of leg length discrepancy (LLD), with its potential of causing several pathological conditions or gait deviations, is well known, measuring LLD is still challenging with limited reliability and validity. OBJECTIVE: To assess the capability of the dynamic leg length (DLL) measurement in detecting the presence of anatomic LLD. METHODS: A lower limb x-ray was performed on 15 participants with suspected LLD in addition to a gait analysis study using a motion analysis system to measure DLL (the absolute distance from the hip joint centre to the heel, to the ankle joint centre and to the forefoot). Average DLLs were compared between sides for symmetry by the paired t-test at 51 sample points during the gait cycle in conjunction with the differences between the sides based on the maximal stance phase and minimal swing phase DLLs. Differences were correlated with anatomic LLD by Pearson correlation. RESULTS: No significant differences in DLLs between sides throughout the gait cycle were found. Significant differences between sides were found between the maximal stance and minimal swing phase DLLs. CONCLUSIONS: DLL measurement is capable of detecting an anatomic leg length difference based on functional changes in leg length and functional discrepancy.
Keywords: Gait analysis, functional, symmetry, dynamic leg length, leg length discrepancy
DOI: 10.3233/THC-192006
Journal: Technology and Health Care, vol. 29, no. 1, pp. 175-185, 2021
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]