Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Advances in Biomedical Engineering: Research that bridges the gap between Engineering and Medicine
Guest editors: Julius Griškevičius.
Article type: Other
Authors: Martinaitis, Arnas* | Daunoraviciene, Kristina
Affiliations: Department of Biomechanical Engineering, Vilnius Gediminas Technical University, Vilnius, Lithuania
Correspondence: [*] Corresponding author: Arnas Martinaitis, Department of Biomechanical Engineering, Vilnius Gediminas Technical University, J. Basanavičius str. 28, MR-II 2-109, 03224 Vilnius, Lithuania. E-mail: [email protected].
Abstract: BACKGROUND: Long sitting causes many health problems for people. Healthy sitting monitoring systems, like real-time pressure distribution measuring, is in high demand and many methods of posture recognition were developed. Such systems are usually expensive and hardly available for the regular user. OBJECTIVE: The aim of study is to develop low cost but sensitive enough pressure sensors and posture monitoring system. METHODS: New self-made pressure sensors have been developed and tested, and prototype of pressure distribution measuring system was designed. RESULTS: Sensors measured at average noise amplitude of a = 56 mV (1.12%), average variation in sequential measurements of the same sensor s = 17 mV (0.34%). Signal variability between sensors averaged at 100 mV (2.0%). Weight to signal dependency graph was measured and hysteresis calculated. Results suggested the use of total sixteen sensors for posture monitoring system with accuracy of < 1.5% after relaxation and repeatability of around 2%. CONCLUSION: Results demonstrate that hand-made sensor sensitivity and repeatability are acceptable for posture monitoring, and it is possible to build low cost pressure distribution measurement system with graphical visualization without expensive equipment or complicated software.
Keywords: Pressure distribution, ergonomics, smart chair, posture monitoring, Velostat sensor
DOI: 10.3233/THC-182512
Journal: Technology and Health Care, vol. 26, no. S2, pp. 655-663, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]