Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Advances in Biomedical Engineering: Research that bridges the gap between Engineering and Medicine
Guest editors: Julius Griškevičius.
Article type: Research Article
Authors: Gaidulis, Gediminasa; * | Votta, Emilianob | Selmi, Matteob; c | Aidietienė, Sigitad | Aidietis, Audriusd | Kačianauskas, Rimantase
Affiliations: [a] Department of Biomechanical Engineering, Vilnius Gediminas Technical University, Vilnius, Lithuania | [b] Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy | [c] Division of Cardiac Surgery, Department of Surgery, Università di Verona, Verona, Italy | [d] Department of Cardiovascular Medicine, Vilnius University, Vilnius, Lithuania | [e] Institute of Mechanics, Vilnius Gediminas Technical University, Vilnius, Lithuania
Correspondence: [*] Corresponding author: Gediminas Gaidulis, Department of Biomechanical Engineering, Vilnius Gediminas Technical University, J. Basanavičiaus 28, LT-03224 Vilnius, Lithuania. Tel.: +370 67820875; E-mail: [email protected].
Abstract: BACKGROUND: Transapical off-pump mitral valve (MV) repair is a novel minimally-invasive surgical technique, allowing to correct mitral regurgitation (MR) caused by chordae tendineae rupture. While numerical simulation of the MV structure has proven to be useful to evaluate the effects of the MV surgical repair techniques, no numerical simulation studies on the outcomes of transapical MV repair have been done up to now. OBJECTIVE: The purpose of this study is to evaluate the transapical MV repair using finite element modeling and to determine the effect of the neochordal length on the function of the prolapsing MV. METHODS: The reconstruction of the MV geometry based on the patient-specific data was performed. In order to simulate prolapse, chordae inserted into the middle segment of the posterior leaflet (P2) were ruptured. A total of four virtual transapical repairs using neochordae of different length were performed. The function of the MV before and after virtual repairs was simulated. RESULTS: The evaluation of the effect of the neochordal length on post-repair MV function showed that the length of the implanted neochordae has a significant impact on the correction of MR caused by chordae tendineae rupture. CONCLUSIONS: The presented results can improve the understanding of the effects of transapical MV repair.
Keywords: Mitral valve, prolapse, transapical, neochordae, finite element model
DOI: 10.3233/THC-182510
Journal: Technology and Health Care, vol. 26, no. S2, pp. 635-645, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]