Issue title: Advances in Biomedical Engineering: Research that bridges the gap between Engineering and Medicine
Guest editors: Julius Griškevičius.
Article type: Research Article
Authors: Staškūnienė, Miglė | Kačeniauskas, Arnas* | Maknickas, Algirdas | Starikovičius, Vadimas | Stupak, Eugeniuš | Pacevič, Ruslan
Affiliations: Vilnius Gediminas Technical University, Vilnius, Lithuania
Correspondence: [*] Corresponding author: Arnas Kačeniauskas, Department of Graphical Systems, Vilnius Gediminas Technical University, Saulėtekio al. 11, 10223 Vilnius, Lithuania. Tel.: +370 5 274 4913; E-mail: [email protected].
Abstract: BACKGROUND: Simulation divergence due to the backflow through the outlet boundary is a common, but not fully addressed challenge in patient-specific simulations of the aortic valve flows. OBJECTIVE: The purpose of this study is to develop the outlet boundary conditions aiming to improve convergence of the patient-specific aortic valve computations and to control the backflow in the case of partial reversal of the flow through the outlet. METHODS: Haemodynamic analysis of the aortic valve flows governed by the Navier-Stokes equations is performed by using the finite volume method. The pressure distribution, obtained from the convergent computations driven by the outflow boundary condition, is approximated by the parabolic surface of revolution and prescribed on the outlet as the novel pressure boundary condition. RESULTS: Various types of outlet boundary conditions are investigated to evaluate their influence on the resulting backflows. The outflow boundary condition produces a smaller backflow than other investigated boundary conditions, but it causes the solution divergence. The proposed outlet boundary condition allows for continuing the solution and preserving the expected backflow. CONCLUSIONS: The proposed outlet boundary condition helps to achieve a convergent solution and to conserve the observed backflow by varying the convexity of the specified pressure surface.
Keywords: Aortic valve, backflow, outlet boundary conditions, patient-specific computations
DOI: 10.3233/THC-182502
Journal: Technology and Health Care, vol. 26, no. S2, pp. 553-563, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]