Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Zhang, Yiwena; b | Gao, Zhuofeia; b | Liu, Wenzhua; b | Gao, Yueminga; b; * | Du, Minb; c
Affiliations: [a] Key Lab of Medical Instrumentation and Pharmaceutical Technology of Fujian Province, Fuzhou University, Fuzhou, Fujian, China | [b] College of Physics and Information Engineering, Fuzhou University, Fuzhou, Fujian, China | [c] Key Lab of Eco-Industrial Green Technology of Fujian Province, Nanping, Fujian, China
Correspondence: [*] Corresponding author: Yueming Gao, Key Lab of Medical Instrumentation and Pharmaceutical Technology of Fujian Province, Fuzhou University, Xueyuan Road No. 2, Fuzhou, Fujian 350116, China. Tel.: +86 13599067568; E-mail: [email protected].
Abstract: BACKGROUND: Recently, health care and disease prevention are more and more important in people’s daily life. Human body communication (HBC) is an emerging short distance wireless communication mode, which is quite suitable for the communication between the wearable human health care equipment. However, most research on HBC mainly focuses on the electromagnetic model and the circuit model of equivalent human and the in vivo experiment is based on the commercial equipment. OBJECTIVE: The aim of this paper is to design a circuit device for measuring the attenuation of the human body channel based on a floating-ground-electrode method. METHODS: This paper proposed a new floating-ground-electrode method so as to solve problems of power and high frequencies interference and impedance matching. A circuit module, including signal generator, analog frontend circuit and MCU, was designed to initially replace the spectrum analyzer to measure the attenuation of the human body channel. The floating-ground-electrode added to the receiving end of the human body channel was connected to the ground of the analog frontend circuit, forming an equal potential circuit. The three-electrodes of the receiving terminal can act as a differential probe, since one electrode is connected to the ground and the other two electrodes achieved signal input and output respectively. RESULTS: The results showed that the experimental data of channel attenuation were similar to the measured value of the spectrum analyzer. The maximum absolute error was 1.148 dB and the relative error was 3.55%. In addition, different sizes of the floating-ground-electrode cannot affect the attenuation path of human body channels. Moreover, the common mode rejection ratio (CMRR) was approximated to the value of the commercial differential probe. CONCLUSION: This paper proposed a new floating-ground-electrode method for measuring the attenuation of the human body channel. It could provide the possibility for the dynamic measurement of attenuation and take the place of the spectrum analyzer and make the process of experiments simple and efficient.
Keywords: Human body communication, galvanic coupling, channel attenuation, floating-ground-electrode
DOI: 10.3233/THC-181533
Journal: Technology and Health Care, vol. 28, no. 3, pp. 275-281, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]