Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Sun, Lixin | Sun, Yingfei* | Huang, Zhipei | Hou, Jiateng | Wu, Jiankang
Affiliations: School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, China
Correspondence: [*] Corresponding author: Yingfei Sun, School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences Huairou District, Beijing, China. Tel.: +86 13661386556; E-mail: [email protected].
Abstract: BACKGROUND: Hill-type musculotendon models are most commonly used in biomechanical simulations for their computational efficacy and efficiency. But these models are generally built for maximally-activated muscles and linearly scale muscle properties when applied to submaximal conditions. However, the precondition of this scaling, which is muscle activation and properties are independent each other, has been proven unreal in many studies. Actually, the maximal activation condition is not ubiquitous for muscles in vivo, so it is necessary to adapt the linear scaling approach to improve the model practicability. OBJECTIVE: This paper aimed at proposing two improved Hill-type musculotendon models that are better suited for submaximal conditions. METHOD: These two models were built by including the activation-force-length coupling and their biological accuracy and computation speed were evaluated by a series of benchmark simulations. RESULTS: Compared to experimental measurements, the percent root mean square errors of forces calculated by the two AFLC models were less than 13.98% and 13.81% respectively. However, the average running time of the second AFLC model was nearly 17 times that of the first one with only a little improvement in accuracy. CONCLUSION: The two AFLC models were validated more accurate than the common Hill-type model in submaximally activated conditions and the first one was recommended in the construction of upper-layer musculoskeletal models.
Keywords: Hill-type model, musculotendon model, activation force-length coupling, submaximal activation
DOI: 10.3233/THC-181267
Journal: Technology and Health Care, vol. 26, no. 6, pp. 909-920, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]