Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Papers from the International Multi-Conference on Engineering and Technology Innovation 2016 (IMETI2016), 28 Oct.–1 Nov. 2016, Taichung, Taiwan
Guest editors: Wen-Hsiang Hsieh
Article type: Research Article
Authors: Kim, Hyungseupa | Park, Yunjonga | Ko, Youngwoona | Mun, Yeongjina | Lee, Sangminb; * | Ko, Hyounghoa; *
Affiliations: [a] Department of Electronics Engineering, Chungnam National University, Daejeon, Korea | [b] Department of Biomedical Engineering, Kyung Hee University, Yongin, Korea
Correspondence: [*] Co-corresponding authors: Hyoungho Ko, Department of Electronics Engineering, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Korea. Tel.: +82 42 821 5664; Fax: +82 42 823 5436; E-mail: [email protected];SangminLee,CollegeofElectronics&Information,KyungHeeUniversity,Giheung-Gu,Yongin17104,Korea.Tel.:+82312012568;Fax:+82312048115;E-mail:[email protected].
Abstract: BACKGROUND: Wearable healthcare systems require measurements from electrocardiograms (ECGs) and photoplethysmograms (PPGs), and the blood pressure of the user. The pulse transit time (PTT) can be calculated by measuring the ECG and PPG simultaneously. Continuous-time blood pressure without using an air cuff can be estimated by using the PTT. OBJECTIVE: This paper presents a biosignal acquisition integrated circuit (IC) that can simultaneously measure the ECG and PPG for wearable healthcare applications. METHODS: Included in this biosignal acquisition circuit are a voltage mode instrumentation amplifier (IA) for ECG acquisition and a current mode transimpedance amplifier for PPG acquisition. The analog outputs from the ECG and PPG channels are muxed and converted to digital signals using 12-bit successive approximation register (SAR) analog-to-digital converter (ADC). RESULTS: The proposed IC is fabricated by using a standard 0.18 μm CMOS process with an active area of 14.44 mm2. The total current consumption for the multichannel IC is 327 μA with a 3.3 V supply. The measured input referred noise of ECG readout channel is 1.3 μVRMS with a bandwidth of 0.5 Hz to 100 Hz. And the measured input referred current noise of the PPG readout channel is 0.122 nA/√Hz with a bandwidth of 0.5 Hz to 100 Hz. CONCLUSIONS: The proposed IC, which is implemented using various circuit techniques, can measure ECG and PPG signals simultaneously to calculate the PTT for wearable healthcare applications.
Keywords: Biosignal acquisition, simultaneous biosignal acquisition, electrocardiogram (ECG), photoplethysmogram (PPG), pulse transit time (PTT), chopper stabilization
DOI: 10.3233/THC-171401
Journal: Technology and Health Care, vol. 26, no. 1, pp. 3-9, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]