Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Ahmad, Husna Azyan Bintia | El-Badawy, Ismail M.b; c | Singh, Om Prakasha; * | Hisham, Rozana Bintia | Malarvili, M.B.a
Affiliations: [a] Biosignal Processing Research Group, Faculty of Bioscience and Medical Engineering, Universiti Teknologi Malaysia, Johor, Malaysia | [b] Faculty of Electrical Engineering, Universiti Teknologi Malaysia, Johor, Malaysia | [c] Electronics and Communications Engineering Department, Arab Academy for Science and Technology, Cairo, Egypt
Correspondence: [*] Corresponding author: Om Prakash Singh, Biosignal Processing Research Group, Faculty of Bioscience and Medical Engineering, Universiti Teknologi Malaysia, Skudai, Johor, Malaysia. Tel.: +60 7 5535982; E-mail: [email protected].
Abstract: BACKGROUND: Fetal heart rate (FHR) monitoring device is highly demanded to assess the fetus health condition in home environments. Conventional standard devices such as ultrasonography and cardiotocography are expensive, bulky and uncomfortable and consequently not suitable for long-term monitoring. Herein, we report a device that can be used to measure fetal heart rate in clinical and home environments. METHODS: The proposed device measures and displays the FHR on a screen liquid crystal display (LCD). The device consists of hardware that comprises condenser microphone sensor, signal conditioning, microcontroller and LCD, and software that involves the algorithm used for processing the conditioned fetal heart signal prior to FHR display. The device’s performance is validated based on analysis of variance (ANOVA) test. RESULTS: FHR data was recorded from 22 pregnant women during the 17th to 37th week of gestation using the developed device and two standard devices; AngelSounds and Electronic Stethoscope. The results show that F-value (1.5) is less than F𝑐𝑟𝑖𝑡, (3.1) and p-value (p> 0.05). Accordingly, there is no significant difference between the mean readings of the developed and existing devices. Hence, the developed device can be used for monitoring FHR in clinical and home environments.
Keywords: Fetal heart rate, condenser microphone, Arduino, gestation, stillbirths
DOI: 10.3233/THC-171067
Journal: Technology and Health Care, vol. 26, no. 4, pp. 573-579, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]