Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Tian, Binga | Jing, Quan-Minb; * | Dong, Haib | Guan, Shao-Yib | Wang, Gengb | Xu, Kaib | Liu, Hai-Weib | Wang, Binb | Sui, Li-Youc
Affiliations: [a] Department of Cardiology, Central Hospital of Shengyang Medical College, Shenyang, Liaoning 110024, China | [b] Department of Cardiology, General Hospital of Shenyang Military Region, Shenyang, Liaoning 110024, China | [c] Department of Cardiology, 1st Hospital of Siping, Jilin 136001, China
Correspondence: [*] Corresponding author: Quan-Min Jing, General Hospital of Shenyang Military Region, 83 Wenhua Rd, Shenyang, Liaoning, China. Tel.: +86 24 28886666; Fax: +86 24 28856114; E-mail: [email protected].
Abstract: OBJECTIVE: This study aims to investigate failure factors in retrograde wire-guided cannulation (retrograde approach) for the treatment of coronary chronic total occlusion (CTO). METHODS: Data of 285 patients treated for CTO using retrograde approach in the General Hospital of Shenyang Military Region from August 2004 to May 2016 were collected. RESULTS: The average age of the 285 patients was 63.89 ± 11.3 years old. Multivariate analysis revealed that the operation risk factors include the number of diseased vessels, collateral circulation, as well as whether anterograde intervention for CTO target vessels was previously performed (OR = 0.875, 95% CI = 0.779–0.940, P= 0.026) and whether other vessels were intervened (OR = 22.372, 95% CI = 2.059–243.031, P= 0.011). CONCLUSION: Based on the present study, the success rate of retrograde approach for CTO was negatively correlated with the number of diseased vessels and collateral circulation. It was furthermore of importance whether anterograde intervention for CTO target vessels was previously performed and whether other vessels beside CTO vessels were intervened, which were also risk factors.
Keywords: Coronary heart disease, PCI, chronic total occlusion, retrograde wire-guided cannulation, ejection fraction
DOI: 10.3233/THC-170946
Journal: Technology and Health Care, vol. 28, no. 1, pp. 13-22, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]