Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Mo, Jun-Cong | Huang, Jin | Gu, Wen-Dong | Gao, Min | Ning, Zhong-Hua | Mu, Jin-Ming | Li, Qi-Lin | Pei, Hong-Lei*
Affiliations: Department of Radiation Oncology, The Third Affiliated Hospital, Soochow University, Changzhou 213003, Jiangsu, China
Correspondence: [*] Corresponding author: Hong-Lei Pei, Department of Radiation Oncology, The Third Affiliated Hospital, Soochow University,185 Juqian Road, Changzhou 213003, Jiangsu, China. E-mail: [email protected].
Abstract: OBJECTIVE: To compare the dosimetric and efficiency differences for left-sided breast cancer radiotherapy after breast-conserving surgery among three different planning techniques: double-arc volumetric-modulate arc therapy (VMAT), step-shoot intensity-modulated radiotherapy (sIMRT) and three-dimensional conformal radiation therapy (3D-CRT). MATERIALS AND METHODS: A total of 17 female patients with left-sided breast cancer who underwent breast-conserving surgery were selected; the prescription doses were 50 Gy in 25 fractions. For every patient VMAT, sIMRT and 3D-CRT plans were generated within the Monaco treatment planning system for an Axesse™ accelerator equipped with the Agility MLC. The Conformity Index (CI), the Homogeneity Index (HI), the dose volume histogram (DVH) parameters for the organs at risk and the delivery efficiency were evaluated. RESULTS: The VMAT plans showed on average higher CI of PTV (0.77 ± 0.03) than both sIMRT (0.68 ± 0.02) and 3D-CRT (0.55 ± 0.04) plans (P< 0.05). The HI values in the VMAT, sIMRT and 3D-CRT plans were 0.10 ± 0.01 0.09 ± 0.01 and 0.13 ± 0.01 (P> 0.05), respectively, and the differences among the three techniques were not statistically significant. In the ipsilateral lung, the VMAT plans showed lower Dmean, V30, V20, and V10 than the sIMRT and 3D-CRT (P< 0.05); however, there was no significant difference in V5. In the heart, the VMAT plans had lower V30 and V20 than the sIMRT and 3D-CRT plans (P< 0.05), but there was no significant difference in the Dmean and V5. In the contralateral lung, the VMAT plans showed higher Dmean and V5 than sIMRT and 3D-CRT (P< 0.05). In the contralateral breast, the VMAT plans had a higher V5 than the sIMRT and 3D-CRT plans (P< 0.05). The VMAT plans had higher MU’s than sIMRT and 3D-CRT, while the treatment times were lower than that of sIMRT. CONCLUSION: For left-sided breast cancer radiotherapy after breast-conserving surgery, the VMAT plans had a better CI than the sIMRT and 3D-CRT plans. The VMAT and the sIMRT plans had better HI than the 3D-CRT plans, but no significant difference was observed between VMAT and sIMRT.
Keywords: Left-sided breast-conserving surgery, double-arc volumetric arc therapy, step-shoot intensity modulated radiotherapy, 3D-CRT, dosimetry
DOI: 10.3233/THC-160746
Journal: Technology and Health Care, vol. 25, no. 5, pp. 851-858, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]