Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Struwe, Charlotte1 | Hermann, Pia C.1 | Bornemann, Rahel | Plöger, Milena | Roessler, Philip P. | Strauss, Andreas C. | Rommelspacher, Yorck | Koch, Ernst M.W. | Pflugmacher, Robert*
Affiliations: Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Bonn, Bonn, Germany
Correspondence: [*] Corresponding author: Robert Pflugmacher, Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Bonn, Sigmund-Freud-Str. 25, 53105 Bonn, Germany. Tel.: +49 0151 58 233 263; Fax: +49 0228 287 14175; E-mail: [email protected].
Note: [1] Both authors contributed equally.
Abstract: BACKGROUND: Spinal fusion surgery has become one of the most common spinal procedures during the recent years. Searching for an optimum structural stability of the vertebral interspace, surgical implants which can be inserted via a posterior lumbar interbody fusion (PLIF) approach have been enhanced recently. OBJECTIVE: Evaluation of safety and efficacy of a novel PLIF polyetheretherketone (PEEK) interbody cage (TWIST) with an impactionless insertion technique. METHODS: Surgical outcome in 15 patients treated with the new system were observed preoperatively, one and three years after surgery using the Oswestry Disability Index (ODI), a Visual Analogue Scale (VAS) for pain and radiological outcome analysis of fusion success. RESULTS: Fifteen patients (7 female, 8 male) were included in the test series. After three years ODI and VAS were significantly improved. The pain intensity was reduced by more than 75% after one year and after 3 years, pain intensity was about 60% below the initial situation. The Oswestry values (ODI) improved significantly in all patients after 3 years. The fusion evaluation showed a fusion success in 87% of the patients. CONCLUSION: The clinical and radiological results of this first series give a positive standing and important information on the efficacy and safety over 3 years. The follow-up checks with imaging techniques showed that the fusions were very successful and functional outcome as well as pain reduction were increased.
Keywords: Spine, chronic low back pain, posterior lumbar interbody fusion (PLIF), interbody cage
DOI: 10.3233/THC-160721
Journal: Technology and Health Care, vol. 25, no. 5, pp. 949-957, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]